Loading ...
Loading ...
Loading ...
ge.com
Problem
Saltg tasting or
brown/gellow colored
water after installation
Brown/yellow
colored water
Resin beads showing
up in drinking water
and sink
Possible Causes
Unit not sanitized
What To Do
Complete the Sanitizotion procedures on page !3.
At completion of rechQrgecycle (Qpprox.2 hrs),run water
from faucets to purge the sQItywater.
Low water pressure Check pressure.
DrQinheight 8' or less,pressureshould be minimum of 20 psi.
DrQinheight above 8', pressureshould be minimum of 50 psi.
Restricted drain hose Cleon and reconnect hose.
Check for kinks indrain line.
Unit was idle for a period of time Complete the Sanitizotion Procedureson pQge15.
Cracked distributor Coilfor service.
Sounds gou might hear Running water from the unit This is normal.
into a drain during recharge
Water has air bubbles Air in sgstem after installation Will go away after it runs for a while.
and is cloudg
Error Code on control Wiring meg have worked loose
in the control
See pQge17for details.
Unplug transformer.
Removecontrol cover,releQseclips on side.
Check for loose/incorrect wiring connections to electronic
boQrdor switch. Reconnect as required.
ReQssemblecontrol cover.
Plugin Transformer.
Wait six minutes for Error Codeto reQppeQr.
If Error Code reQppeQrs,call for service.
Blue light flashing
When power applied Control needs to be programmed See the Progromming the Contro! section, pQge lO.
to the sgstem (a power outage mag have occurred}
If"DAYS TO EMPTY" Low salt level, less than 15 dags Fillwith sQIt.
is flashing Reset sQIt level.
If"Err" in display Electrical problem with sgstem See pQge 17 for details.
See procedure above, Error code on control.
23
Loading ...
Loading ...