ge.com
Problem
Saltg tasting or
brown/gellow colored
water after installation
Brown/yellow
colored water
Resin beads showing
up in drinking water
and sink
Possible Causes
Unit not sanitized
What To Do
• Complete the Sanitizotion procedures on page !3.
• At completion of rechQrgecycle (Qpprox.2 hrs),run water
from faucets to purge the sQItywater.
Low water pressure Check pressure.
• DrQinheight 8' or less,pressureshould be minimum of 20 psi.
• DrQinheight above 8', pressureshould be minimum of 50 psi.
Restricted drain hose • Cleon and reconnect hose.
• Check for kinks indrain line.
Unit was idle for a period of time • Complete the Sanitizotion Procedureson pQge15.
Cracked distributor • Coilfor service.
Sounds gou might hear Running water from the unit • This is normal.
into a drain during recharge
Water has air bubbles Air in sgstem after installation • Will go away after it runs for a while.
and is cloudg
Error Code on control Wiring meg have worked loose
in the control
• See pQge17for details.
• Unplug transformer.
• Removecontrol cover,releQseclips on side.
• Check for loose/incorrect wiring connections to electronic
boQrdor switch. Reconnect as required.
• ReQssemblecontrol cover.
• Plugin Transformer.
• Wait six minutes for Error Codeto reQppeQr.
• If Error Code reQppeQrs,call for service.
Blue light flashing
When power applied Control needs to be programmed • See the Progromming the Contro! section, pQge lO.
to the sgstem (a power outage mag have occurred}
If"DAYS TO EMPTY" Low salt level, less than 15 dags • Fillwith sQIt.
is flashing • Reset sQIt level.
If"Err" in display Electrical problem with sgstem • See pQge 17 for details.
• See procedure above, Error code on control.