INSTALLATION
Electrical connection
Rear view All Cooktops
Electrical
connection
mm)
Terminal
Block
(40
Gas Inlet Male
1 1/2“
1/2 NPT connection
7 5/8“
(195 mm)
1. NAMEPLATE LABEL
The nameplate label of your appliance is on the bottom-left, on
the toe kick behind the storage drawer, or inside the spill tray for
the Château 120 models and for the standalone cooktops. To see
this rating plate, pull out the storage drawer or spill tray.
You will find on this plate the name and address of the
manufacturer as well as the following information:
1) Kind of appliance (Model )
2) Serial number (order number)
3) Manufacturing date
4) Total gas rating BTU/hr
5) Type of gas and Manifold pressure
6) Burner input rating BTU/hr for each burner
7) Voltage rating in Volt, Total Electric Power in Watts and Intensity (Amps)
2. ELECTRICAL CONNECTION
The appliance must be electrically installed and grounded in accordance with local codes or in the
absence of such codes with the latest edition of the ”National Electrical Code”, ANSI/NFPA 70 in the
USA, and CSA C22.1 ”Canadian Electrical Code” - in Canada.
Disconnect all the power supply circuits before accessing the junction boxes.
This appliance must be supplied with 240 Volt (or 120 Volt for some cooktops) and 60 Hz frequency, and
connected to an individual, properly grounded branch circuit, protected by a circuit breaker or time-delay
fuse, as noted on the rating plate.
Use only a 3-wire or a 4-wire UL-listed power-supply cord rated 120/240 Volts with a strain relief and
marked for use with ranges.
The specified ampere rating for the cord shall be 30, 40, or 50 A, in accordance with Table below:
Range rating,
Specified rating of
W
power-supply-cord kit
120/240 V 3-wire
A
0 8,749
30
8,750 16,500
40
16,501 22,500
50
Only a 4 wire cord is to be used when the appliance is installed where grounding through the neutral
conductor is prohibited, such as:
- new branch-circuit installations (1996 NEC),
LA CORNUE
Installation Guide Château G4 - USA Canada
Page
49
USA & C
ANADA
08NOTINSG4/ULC-1