EX17DT and EX22DT Installation and Operation Manual 17
3 screws
Sleeve should extend
3/16 - 3/8 in (5-10 mm)
3. Install the Sleeve.
Attach the sleeve to the inside wall using 3 screws arranging the flange so that the marking
“TOP” is at the top. The flange is offset 2° to allow the condensate drain to the outside.
Apply silicone sealing evenly around the perimeter of the outside sleeve to avoid water intrusion.
Figure 11
Indoor
Outdoor
Apply silicone
sealing evenly
around the
perimeter.
4. Install the Terminal.
Check that the terminal seal is in place. For weatherboard walls, add the second seal next to the
terminal seal to compensate for weather board angle. Adjust the second seal to make sure “Top”
marking of the second seal is located at the top or “Ʌ” marking is aligned with “V” marking on the
terminal.
From the outside insert the terminal into the sleeve with the marking “TOP” at the top. The left
hand side locking tie should be marked “LEFT”.
Top Terminal
seal
Apply silicone
sealing evenly
around the entire
seal.
Put silicone sealing evenly around the perimeter without any
gaps between the terminal seal and rough wall surface.
Figure 12
Locking tie
(Ʌ)
(V)