Chef CRC914DB 90cm Canopy Rangehood

User Manual - Page 7

For CRC914DB.

PDF File Manual, 16 pages, Read Online | Download pdf file

CRC914DB photo
Loading ...
Loading ...
Loading ...
4. Remove the protective plastic film from the hood body
and hang hood on the mounting screws then secure at
the anti-tilt locations as indicated in Fig. 6 & 7.
5. Fix exhaust transition duct using screws supplied
(Fig. 8).
Depending on the preferred installation/ducting mode,
follow step 6a or 6b below.
6a.Recirculating mode (Fig. 9). Using the centre line,
secure the recirculating T-piece to the wall with suitable
pipe between T-piece and the exhaust transition duct.
Use cable ties or suitable duct tape to secure flexible
pipe to T-piece and transition duct (Fig. 11).
NOTE: When installed in recirculating mode, it is
recommended to use a carbon filter (included in
recirculation kit AR910RK) to prevent odours being
emitted back into the room.
6b.Ducted mode (Fig 10.) The rangehood can be
connected with a 150mm diameter non-combustible flue
pipe (rigid or flexible - not included) and fan transition
duct. Continue the centre line to the ceiling. Fit preferred
flue pipe to the fan transition duct. Use cable ties or
suitable duct tape to secure flexible pipe to the transition
duct.
NOTE: For ducted mode, extend the flue pipe through
the roof to external ‘china hat’ to vent exhaust externally.
Do not vent into the ceiling cavity.
NOTE: To ensure optimum performance of the
rangehood, the use of rigid ducting is recommended.
The use of bends should be avoided. Rigid flexible
ducting is suitable, although loose flexible ducting is
unacceptable. All ducting must be fire retardant.
INSTALLATION
Fig. 7
Fig. 9 Fig. 10
Fig. 8
7
Loading ...
Loading ...