COMMERCIAL DEHUMIDIFIER
B-AIR.COM | 877.800.BAIR | WATER DAMAGE RESTORATION DIVISION
VANTAGE LGR 2200
Specifications
WARNING
In the event of a fault code, contact your service agent.
MODEL BPA
Power Source 115V / 60Hz
Water Removal AHAM (80ºF 60%RH) 130 pints/day
Water Removal Max (90ºF 90%RH) 225 pints/day
Rated Current 8.5 amps
Low Side Design Pressure 240 psig
High Side Design Pressure 480 psig
Refrigerant R410a / 26.8 oz.
Max Process Air 400 CFM
Drain Hose Length 30 ft
Dimensions (WxDxH) 21 x 20 x 32.25 inches
Net Weight 100 lbs.
Operating Range 32º - 115ºF
ERROR MESSAGE DISPLAY READING SOLUTION
E0
EEPROM error Blinking display in the first line Reset unit*
Reset unit: Turn unit off, then turn it back on.
E1
Communication error Blinking display in the first line Reset unit
E2
Coil sensor error
Every 30 seconds flashing
display for 2 seconds
The machine can
still work, but
will not detect
refrigerant error
E3
Air-outlet sensor error
Every 30 seconds flashing
display for 2 seconds
The machine can
still work, but
will not detect
refrigerant error
E4
Humidity sensor error
Every 30 seconds flashing
display for 2 seconds
Frequency
reduction,
reset unit
E5
Current protection for
main control plate
Blinking display in
the first line
Frequency
reduction,
reset unit
E6
Air-outlet temperature
protection
Blinking display in
the first line
Reset unit
E7
Over-current protection
for compressor
Blinking display in
the first line
Reset unit
E8
Water pump error
Blinking display in
the first line
Reset unit
P0
IMP module error
Blinking display in
the first line
Frequency
reduction,
reset unit
P1
Voltage too high or too low
Blinking display in
the first line
Reset unit
P2
Compressor stall
Blinking display in
the first line
Reset unit
P3
Refrigerant lack
Blinking display in
the first line
Reset unit