OWNER & OPERATOR INSTRUCTION MANUAL - Page 7

For TARG4B36G. Also, The document are for others Radiance models: TAR-4, TAR-24G, TAR-24RB, TAR-6, TAR-36G, TAR-36RB, TARG-4B12G, TARG-12G4B, TARG-2B24G, TARG-24G2B, TAR-8, TARG-6B12G, TARG-12G6B, TARG-2B36G, TARG-36G2B, TARG-4B24G, TARG-24G4B, TAR-10, TARG-8B12G, TARG-12G8B, TARG-6B24G, TARG-24G6B, TARG-36G4B, TARG-2B48G, TARG-48G2B, TARG-6B24RG, TARG-24RG6B

Loading ...
Loading ...
Loading ...
7
INSTALLATION & OPERATION INSTRUCTION
60” RANGE REQUIRES TWO GAS CONNECTIONS
The gas inlet line size of this unit is ¾” NPT. For proper installation, the gas service supply line must
be the same size or greater than the inlet line size of the unit. Each gas connection or inlet should
have an individual, dedicated line to the main gas supply.
The gas pressure regulator must be installed in each gas line (failure to install a pressure regulator
will void the warranty). The arrow on the bottom of the regulator should be pointing toward the unit
The regulators supplied with ranges have ¾” NPT connections. Be sure the regulator matches the
gas type that is being used on the unit.
- Natural gas: 5” W.C. manifold gas pressure
- Propane gas : 10” W.C. manifold gas pressure
Before connecting the regulator, check the incoming line pressure – as these regulators can only
withstand a maximum inlet pressure of 14” W.C. (exceeding this pressure will damage them).
IMPROPER INSTALLATION
PROPER INSTALLATION
- Natural gas: 5” W.C. manifold gas pressure
- Propane gas : 10” W.C. manifold gas pressure
Loading ...
Loading ...
Loading ...