Pleasecheckthefollowingbeforecallingforservice:
Placeonecupof waterina glassmeasuringcupinthemicrowaveovenandclosethedoorsecurely.
Operatethe microwaveovenforoneminuteat HIGH100%.
A Doesthemicrowaveovenlightcomeon? YES.... NO....
B Doesthecoolingfanwork?(PutyourhandonthelouverabovetheControlPanel.) YES.... NO....
C Doestheturntablerotate?(It is normalfortheturntableto turn in eitherdirection.) YES.... NO....
D Isthewaterin themicrowaveovenwarm? YES NO
If "NO" is the answer to any of the above questions,
please check electrical outlet, fuse and/or circuit
breaker. If they are functioning properly, CONTACT
YOUR NEAREST ELECTROLUX AUTHORIZED SER=
VILER.
A microwave oven should never be serviced by a
"do=it=yourself" repair person.
If time appearing in the display is counting down
very rapidly, check Demonstration Mode on page 27
and cancel.
AC Line Voltage: Single phase 120V, 60Hz, AC only
AC Power Required: 1600W 14.2 amps. (for FGMV173QF, FGMV173QB/W/Q/N)
Output Power*: 1000 W
Frequency: 2450 MHz (Class B/Group2)**
Outside Dimensions: 29 7/8"(W) x 16 13/32"(H) x 15 1/32"(D)
Cavity Dimensions: 2015/16"(W) x 9 7/16"(H) x 14 13/32"(D)
Microwave oven Capacity***: 1.7 Cu.Ft.
Cooking Uniformity: Turntable
Weight: Approx. (net) 61.7 Ib, (gross) 28.0 Ib
Work/Night Light: 2 bulbs 30w each (incandescent light bulbs)
Oven Light: 1 bulb 30w (incandescent light bulbs)
* The International Electrotechnical Commission's standardized method for measuring output wattage. This test method
is widely recognized.
** This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the International Standard CISPRll.
*** Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less.
In compliance with standards set by:
FCC Federal Communications Commission Authorized.
DHHS
NHW
®
CQus
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter ].
Department of National Health and Welfare of Canada.
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. for use in
USA or Canada.