INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.
27
ArtNo.132-0005 - Fixed wiring connection 2 (AUS)
Mains terminal
Fixing bracket for
conduit connection
Conduit
Cable clamp
AN
ArtNo.132-0001 - 1 phase 240Vac 50Hz
1-phase 220-240 V
AC
50 Hz
Fig. 7.10
Fig. 7.11
Fig. 7.12
Fig. 7.13
ArtNo.132-0002 - 3 phase 240/415Vac 50Hz
3-phase 400 V
AC
50 Hz
3-phase 230 V 50 Hz
Pressure Testing
The pressure test point is accessible on the inlet pipe at the
rear. Remove the test nipple screw and t a pressure gauge to
the test point. Turn on and light two of the hotplate burners.
For Natural Gas cookers the pressure should be between
0.95kPa and 1.0kPa.
For Propane X cookers the pressure should be 2.54 kPa.
Electrical Connection
This appliance must be installed by a qualied electrician
to comply with with current AS/NZS 3000 Wiring Rules
and regulations in force.
Make sure that the mains characteristics (voltage, nominal,
power, etc.) match the ratings indicated on the cooker data
plate.
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
Breaker with Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
The cooker is preset for a single-phase earthed electrical
connection. It is essential to install a multi-pole circuit breaker
that completely disconnects the appliance from the mains,
with a minimum contact break distance of 3 mm.
n
WARNING: THIS APPLIANCE MUST BE EARTHED.
The appliance must be connected to an ecient earthing
circuit. If the electricity network is not equipped with an
earth connection, then it must be installed separately in
compliance with local regulations.
Earthing is a safety measure required by law, and must be
performed with particular care by a qualied technician,
who must also check that the electricity supply
characteristics are correct.
The total electrical load of the appliance is approximately
4.44 kW. The cable size used should be suitable for this load
and comply with all local requirements (i.e. PVC Insulated
cable IEC 60227 – code 53 for ordinary cables).
Please note the maximum cable sizes are 6 mm² for the screw
terminals and 10 mm² for the 3-pronged links (Fig. 7.11).
Access to the mains terminal is gained by removing the
electrical terminal cover on the back panel. Connect the
mains cable to the correct terminals for your electrical
supply type (Fig. 7.10 and Fig. 7.12).
Check that the links are
correctly tted and that the terminal screws are tight. Secure
the mains cable using the cable clamp (Fig. 7.13).
An isolation switch shall be provided and mounted near
the cooker, in a readily accessible position, in compliance
with AS/NZS 3000 and/or AS/NZS 5601 as applicable for the
appliance conguration.