INSTALLATION INSTRUCTIONS
(_:_td e_ __d_ _:__:_:_se:_ _:_:_st:a_la_:_o_
Excessive Weight Hazard
Use two or more people to move and install side
burner.
Failure to do so can result in back or other injury.
Unpack side burner. Remove all packaging materials and
remove side burner from carton.
Move side burner close to desired outdoor location.
Make Gas Connection
Natural Gas Use
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1 - latest edition, or
CAN/CGA-B149.1 Natural Gas and Propane installation code.
1. Place side burner into outdoor enclosure, but leave enough
room in back to connect to gas supply and plug in electrical
single-prong plug to the side burner.
Explosion Hazard
Use a new CSA International approved "outdoor"
gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death, explosion, or fire.
3.
4=
Using a wrench to tighten, connect the gas supply to the side
burner. Use pipe-joint compound on all non-flared male
threads. Do not kink or damage the flexible connector when
moving the side burner.
A
............................D
A. 7/2"side burner gas pipe
B. New CSA International approved
"outdoor" flexible gas supply fine
C. Rear of side burner
D. To Natural gas supply
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
5=
A. Closed valve
B. Open valve
Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
2.
A combination of pipe fittings must be used to connect the
side burner to the existing gas line. If local codes permit, use
an outdoor flexible stainless steel tubing gas connector,
design-certified by CSA International, to connect the side
burner to the rigid gas supply line. A 5/8"diameter line is
recommended.
Pipe-joint compounds suitable for use with Natural gas must
be used. Do not use TEFLON ®ttape.
t®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
11