Page 9
Operating
Operating
Instructions
COMFORT button(on some models)
Press to starts/stops the comfort dehumidifying
operation.
Note: On this operation,the unit can not be set
humidity level. For some models, under comfort
dehumidifying operation, press Up/Down button will
cancel this feature.
Other features
· Humidity Set Control buttons
UP/DOWN buttons
· TIMER Set Control buttons
Use the Up/Down buttons to set the Auto start and
Auto stop time from 0.0 to 24.
The humidity level can be set within a range of 35%
RH(Relative Humidity) to 85%RH(Relative Humidity)
in 5% increments. For drier air , press the (or )
button and set to a lower percent value(%). For
damper air, press the (or ) button and set a
higher percent value(%).
POWER button
Press to turn the dehumidifier on and of
f.
PUMP button(on some models)
Press to activate the pump operation.
Note: Make sure the pump drain hose is installed into
the unit and the continuous drain hose is removed
from the unit before the pump operation is activated.
When the bucket is full,the pump starts to work.Refer
to the next pages for removing the collected water. Do
not use this operation when the outdoor temperature
is equel to or less than 0 C (32 F).
Bucket Full Light
Glows when the bucket is ready to be emptied.
Auto Defrost
When forst builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.
proper position.
For some models, the fan motor will continue to run
for 30 seconds.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or
when the bucket is removed or not replaced in the
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
operation in the first 3 minutes.This is to protect the
unit. Operation will automatically start after 3 minutes.
O O
ION button(on some models)
DRYER button(on some models)
Press to activate the ionizer. Anions are automatically
generated by ionization. The anions deactive the
Press to activate the dryer operation. Press it again to
stop the function.
Display
Shows the set % humidity level from 35% to 85% or
auto start/stop time (0~24) while setting, then shows
the actual(±5% accuracy) room % humidity level in a
range of 30% RH(Relative Humidity) to 90%RH(Relative
Humidity).
Error Codes and Protection Code:
AS-Humidity sensor error--Unplug the unit and plug it
back in. If error repeats, call for service.
ES-Tube Temperature sensor of the evaporator error--
Unplug the unit and plug it back in. If error repeats,
call for service.
P2-Bucket is full or bucket is not in right position--
Empty the bucket and replace it in the right
position.(only available for the unit with no pump
feature.)
P2-Bucket is full -- Empty the bucket.(only available for
the unit with pump feature.)
Eb-Bucket is removed or not in right position-- Replace
the bucket in the right position.(only available for
the unit with pump feature.)
Note: When one of the above malfunctions occurs,
turn off the unit, and check for any obstructions.
Restart the unit, if the malfunction is still present, turn
off the unit and unplug the power cord. Contact the
manufacturer or its service agents or a similar qualified
person for service.
airborne chemical vapors and dust particles. Press it
again to stop the function.