OPERATIONS MANUAL
BOTTLE, KEG & BACK BAR COOLERS, GLASS & PLATE CHILLERS
CONDENSATE REMOVAL
All Bar Equipment units contain a factory installed condensate
drain water evaporating pan which is completely self contained
and no further assembly or maintenance is required. On KC24
and BBC24 models, the drain pan and brackets must be attached
by the installer (see Figure 3). For your convenience, only
evaporator condensate drains into this pan and cabinet washout
drainage water has its own hose located behind the front grill for
easy disposal during cabinet cleaning.
CBC Bottle Cooler models are provided with a floor drain in the
storage compartment with a drain hose located behind the front
grill for easy disposal of condensate and water during cleaning.
FIGURE 3: KC24/BBC24 Condensate Pan Install
KC/BBC24 DRAIN PAN INSTALLATION
BRACKET
MOUNTING
SCREWS
KEYSLOT
DRAIN PAN
DRAIN TUBE
FLOOR LOADS
The floor at the final location site must be level, free of vibration
and strong enough to support the total combined weights of
your new model plus the maximum product load which might
be placed into it. To estimate the possible product weight,
assume that each cubic foot of storage space weighs approxi-
mately 35 pounds. Multiply 35 pounds by the amount of cubic
feet in the cabinet to obtain the product load weight.
For example, a 20 cubic foot refrigerator can hold approximately
700 pounds of product (35 x 20). Assuming the cabinet itself
weighs 300 pounds, the total combined weight of cabinet and
product is approximately 1000 pounds. Therefore, the floor in
this example must be able to support up to 1000 pounds.
MOUNTING AND LEVELING
All Bar Equipment units are designed and constructed to be
mounted directly on the floor without legs or casters (see
Figure 2). When mounting directly to floor, the base of the
cabinet should be sealed to the floor around its entire perimeter.
IMPORTANT NOTE: It is extremely important that your
new model is perfectly level for proper operation. If it is
not level, the defrost water will fail to drain properly and
will overflow the evaporator coil drain pan and into the
cabinet of the model.
After removing your unit from the skid, you may carefully slide it
into position. Once the cabinet is positioned in its final location,
check that it is level in all directions. If necessary, insert shims
under the cabinet to make adjustments. Seal base of the cabinet
to the floor around its entire perimeter with NSF approved seal-
ant, to meet sanitation requirements.