Loading ...
Loading ...
Loading ...
DIP SWITCHES
Auxiliary dip switch controls are located behind the front
panel, through an opening below the control panel.
To access, remove front panel. See Fig. 10.
Dip switches are accessible without opening the
control box. Unit must be powered OFF to effectively
change their status.
Factory settings for dip switches will be in the
DOWN position. See Table 4 - Dip Switch Functions
for functions of each dip switch position.
Dipswitch
Switches
Fig.16 -Dipswitch Location on Unit
Freeze guard
Setpoint Limit 2
Setpoint Limit 1
Fan CON/CYC for cooling/Energy Saver: Cooling
Fan CON/CYC for heating/Energy Saver: Heating
Wall Thermostat enable
Electric heat only (for Heat Pumps)
Fig.17 -Dip Switches
Table 4mDIP SWITCH FUNCTIONS
No, UP REHARKS
1 Electric Heat Only For Heat Pump unit only
2 Walt Thermostat Enable
3 Fan Continuous Run for Heating
4 Fan Cycle for Cool
UP*UP
68---75°F
20---24°C
DOWN DEFAULT
Heat Pump DOWN
Control Panel Enable DOWN
Fan Cycle for Heat DOWN
Fan Continuous Run for Cooling DOWN
DOWN*UP DOWN*DOWN
DOWN*DOWN
65---78_F 61---86°F
61---86°F
19---26°C 16---30°C
16---30°C
(full range)
Freeze Guard Enable DOWN
Two configurations (5*6)
Combine to select set
point range.
When set point limit set,
display always shows
full range.
5*6
UP*DOWN
63---80°F
18---28 °C
7 Freeze Guard Disable
1.Electric Heatinq Only / Emergency Heat (For Heat Pump Units Only]
This setting is typically used for Emergency Heating.
2.Wall Thermostat Enable
A wired wall thermostat can be connected to the unit. The dip switch must be adjusted accordingly in order to
allow the wall thermostat control of the unit. When in wall thermostat mode, the control panel will be disabled.
3*4,Energy Saver Dip Switches
Allows the fan to operate in continuous or cycle modes while the unit is in heating or cooling mode
(continuous or cycle):
CON (Continuous)
Allows fan to run continuously, circulating air even when the temperature setting has been satisfied.
CYC (Cycle)/Energy Saver
This setting allows the fan to cycle on and off with the compressor or electric heater. The fan stops a
short time after the temperature setting is satisfied.This is the most efficient mode for electrical usage.
5*6,Setpoint Temperature Limits
Provides a range of temperature control.
7,Room Freeze Protection
If the unit senses a room temperature below 40°F, the fan motor and electric strip heat will turn on and
warm the room to 50°R The fan stops a short time after the temperature is satisfied.
© 2010 Electrolux Home Products,Inc. All rights reserved.