Loading ...
Loading ...
Loading ...
INSTALLATION - 3791477A583/A
e
The nozzles not provided are available at Authorised Service Centres.
Burner and nozzle characteristics table (70-90 cm models)
4 Natural Gas G2.350 - 13 mbar AUX SR UR2
Rated heating capacity (kW) 1.1 1.8 3.6
Nozzle diameter (1/100 mm) 94 120 190
Pre-chamber (printed on nozzle) (Y) (Y) (H1)
Reduced flow rate (W) 400 500 1800
5 LPG G30/31 - 30/37 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.7 3.6
Nozzle diameter (1/100 mm) 50 65 96
Pre-chamber (printed on nozzle) - - (S4)
Reduced flow rate (W) 400 500 1600
Rated flow rate G30 (g/h) 73 124 265
Rated flow rate G31 (g/h) 71 121 257
6 LPG G30/31 - 37 mbar AUX SR UR2
Rated heating capacity (kW) 1.1 1.8 3.5
Nozzle diameter (1/100 mm) 50 65 80
Pre-chamber (printed on nozzle) - - (F4)
Reduced flow rate (W) 450 550 1800
Rated flow rate G30 (g/h) 80 131 254
Rated flow rate G31 (g/h) 79 129 250
7 Town gas G110 – 8 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.7 3.5
Nozzle diameter (1/100 mm) 145 185 270
Pre-chamber (printed on nozzle) /8 /2 -6
Reduced flow rate (W) 400 500 1400
1 Natural Gas G20 - 20 mbar AUX SR RR UR2
Rated heating capacity (kW) 1.0 1.8 2.6 4.0
Nozzle diameter (1/100 mm) 72 97 108 150
Pre-chamber (printed on nozzle) (X) (Z) (Y) (H3)
Reduced flow rate (W) 400 500 800 1800
2 Natural Gas G20 - 25 mbar AUX SR RR UR2
Rated heating capacity (kW) 1.0 1.8 2.6 4.0
Nozzle diameter (1/100 mm) 72 94 105 145
Pre-chamber (printed on nozzle) (X) (Z) (Y) (F3)
Reduced flow rate (W) 400 500 750 1400
3 Natural Gas G25.1 - 25 mbar AUX SR RR UR2
Rated heating capacity (kW) 1.1 1.8 2.6 3.9
Nozzle diameter (1/100 mm) 77 100 124 148
Pre-chamber (printed on nozzle) (F1) (Y) (F3) (F3)
Reduced flow rate (W) 400 500 800 1400
4 Natural Gas G2.350 - 13 mbar AUX SR RR UR2
Rated heating capacity (kW) 1.0 1.8 2.5 3.9
Nozzle diameter (1/100 mm) 94 120 152 200
Pre-chamber (printed on nozzle) (Y) (Y) (F3) (H1)
Reduced flow rate (W) 400 500 800 1400
Loading ...
Loading ...