3 Additional requirements for Freestanding and Elevated Cooking
Appliaces (Measurements D & E)
Where D, the distance from the periphery of the nearest burner to a
horizontal combustible surface is less than 200 mm, then E shall be 10 mm or
more, or the horizontal surface shall be above the trivet. See insets above.
NOTES
1 Requirement 3 does not apply to a freestanding or elevated cooking appliance which
is designed to prevent flames or the cooking vessels from extending beyond
the periphery of the appliance.
2 The ‘cooking surface area’ is defined as that part of the appliance
3 where cooking normally takes place and does not include
those
parts
of the appliance
containing control knobs.
4 For definition of hob, see Clause 1.4.64.
5 For definition of trivet, see Clause 1.4.109.
6 Consideration is to be given to window treatments when located near cooking
appliances. See Clause 5.3.4.
7.3 Combustion gas discharge
Combustion gases may be discharged by means of hoods connected to a flue
with reliable natural draught, or a fan extraction system. An effective extraction
system requires careful design by an authorised specialist, and must comply
with the regulation distances and positions. After installation, the engineer must
issue a certificate of compliance.