Component description
Components and measurement values
The specified resistance values apply at room temperature (about 20°C/6F). Values within
±10% are considered normal.
Article no. Component Measurement value Comment
80 839 15 Motor 50 Hz,
220/240 V
Winding฀resistance:
cable colour red-white 26.5
cable colour red-blue 53.5
cable colour white-blue
27.0
Current:฀0.7฀A;฀140฀W;฀
2850 rpm
80 839 16 Motor 60 Hz,
220/240 V
Winding฀resistance:
cable colour red-white 26.5
cable colour red-blue 53.5
cable colour white-blue
27.0
Current:฀0.7฀A;฀140฀W;฀
3300 rpm
The motor is a 2-pin motor and is
directly connected to the fan for
internal air and the gearing for driving
the cylinder. On condenser dryers, the
motor also drives the fan for external air.
80 903 13 Capacitor 8 µF 50 Hz
80 903 14 Capacitor 6 µF 60 Hz
80 902 70 Capacitor heat pump 17 µF 50 Hz
80 902 71 Capacitor heat pump 60 Hz
80 821 28 Condensate pump 50 Hz
80 846 48 Condensate pump 60 Hz
80 762 02 EMC-filter with inductor The filter eliminates interference to and
from the machine.
80 833 44 Thermistor 4.8 k (at 25°C) The thermistor controls temperature
regulation. If the thermistor is short-
circuited or detaches from the control
unit, the programme is stopped.
80 773 85 Thermostat 150 150°C automatic The thermostat/overheating cut-out
stops the programme if the temperature
becomes too high.
80 792 00 Thermostat 135 135°C automatic
80 902 24 Thermostat 110 110°C automatic
80 761 04 Door switch The front door triggers a door switch
which stops the programme when the
door is open. If the door has been opened
and closed during the programme the
machine must be restarted using the
Start/Stop button.
80 761 03 Microswitch float
Overflow guard
If both containers in the tumble dryer
are full the programme is stopped by
a float switch installed in the lower
container. “Over flow” is indicated on
the display.
Electrical connection Condenser 1950W/10A-
2500W/16A
Vented 1950W/10A-
3000W/16A
Heat pump 1300W/10A
Heating Water Circuit
1950W/10A
The machine is delivered as single phase
and can be switched between 10 A and 16
A. The control buttons are used to make
the switch via the software. Does not apply
to Heat Pump or Heating Water Circuit.
Service Manual TD70.C
9