Service menu cont.
Turn/
Push
Display Comments/instructions
Test No component tested
DIAGNOSTICS
Test motor The motor runs at normal speed
Test heater 1 The motor runs at normal speed. Heating element 1 is switched on and off by the CU
depending on the values registered by thermistors 1 and 2. Max. temp. 70°C. (Only if
setting for heat pump is Heat Pump Off )
Test heater 2 The motor runs at normal speed. Heating element 2 is switched on and off by the CU
depending on the values registered by thermistors 1 and 2. Max. temp. 70°C. (Only for
condenser and vented machines and where setting for steam is Steam Off)
Testing compressor Temperature sequence on (only machines with heat pump)
Testing switching valve Switching valve on (only machines with heat pump)
Testing fan/HWC Fan/Valve on (Fan only for machines with heat pump and Valve only for HWC)
Test drain The condensed water pump starts (only condenser machines and heat pump)
Test buzzer Buzzer on continuously
Dry level 0 Drying time extended by 0, default setting
DRY LEVEL
Dry level +5 Drying time extended by 5 min
Dry level +10 Drying time extended by 10 min
Dry level +15 Drying time extended by 15 min
Dry level +20 Drying time extended by 20 min
Auto extra dry Off Setting to make Programme 1 - Auto extra dry selectable/non-selectable in the
programme menu.
BLOCK฀PROGRAMS
On
Auto dry Off Setting to make Programme 2 - Auto dry selectable/non-selectable in the programme
menu.
On
Auto normal dry Off Setting to make Programme 3 - Auto normal dry selectable/non-selectable in the
programme menu.
On
Auto extra dry
Off Setting to make Programme 4 - Auto extra dry, low temperature selectable/non-
selectable in the programme menu.
On
Auto dry
Off Setting to make Programme 5 - Auto dry, low temperature selectable/non-selectable
in the programme menu.
On
Auto normal dry
Off Setting to make Programme 6 - Auto normal dry, low temperature selectable/non-
selectable in the programme menu.
On
Auto iron dry
Off Setting to make Programme 7 - Auto iron dry, low temperature selectable/non-
selectable in the programme menu.
On
Coin Off Setting for coin operations Off, default setting
COIN
Coin On Setting for coin operations On
S3
J1 DISPLAY
S2
S1
Service Manual TD70.C