Base Grille Water Filtration System
Model PIKB1/PIRFKB1 Capacity 100 Gallons (379 Liters)
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane,
Tetrachloroethylene, Endrin, Alachlor, Styrene, Chlorobenzene, Ethylbenzene, TTHM, MTBE and VOC.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53.
Substance Reduction
Aesthetic Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
Atrazine
Asbestos
Live Cysts _
Turbidity
Alachlor
Endrin
Ethylbenzene
Lindane
Chlorobenzene
Tetrachloroethylene
Styrene
TTH M
MTBE
VOC
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.005 mg/L
0.6 mg/L
0.003 mg/L
0.003 mg/L
99%
>99.95%
0.5 NTU
0.002 mg/L
0.002 mg/L
0.7 mg/L
0.0002 mg/L
0.1 mg/L
0.005 mg/L
0.1 mg/L
0.080 mg/L
0.005 mg/L
0.05 mg/L
Average
Influent
2.10 mg/L
21000000#/m L
Average
Influent
150 ug/L
160 ug/L
5.8 ug/L
6.1 ug/L
15 ug/L
1900 ug/L
14 ug/L
9.0 ug/L
130 MFL
96,000/L
12 NTU
41 ug/L
5.9 ug/L
2100 ug/L
1.9 ug/L
2100 ug/L
14 ug/L
2200 ug/L
480 ug/L
15 ug/L
300 ug/L
Influent Challenge Maximum Minimum %
Concentration Effluent Reduction
2.0 mg/L + 10% 0.05 mg/L ** 97.6
At east 10,000 part c es/mL 140000 #/mL 99
Influent Challenge
Concentration
0.15 mg/L + 10%
0.15 mg/L_+ 10%
0.006 mg/L + 10%
0.006 mg/L _+10%
0.015 mg/L_+ 10%
1.8 mg/L _+10%
0.015 mg/L_+ 10%
0.009 mg/L _+10%
107to 108fibers/l_ tt
50,000/L min.
11 _+1 NTU
0.04 mg/L _+10%
0.006 mg/L _+10%
2.1 mg/L_+ 10%
0.002 mg/L _+10%
2.0 mg/L _+10%
0.015 mg/L_+ 10%
2.0 mg/L _+10%
0.45 + 20%
0.015 _+20%
300 _+30 ug/L
Maximum
Effluent
1.0 ug/L
2.0 ug/L
0.2 ug/L
0.4 ug/L
0.5 ug/L
0.7 ug/L
1.0 ug/L
0.5 ug/L
0.17 MFL
1/U
0.4 NTU
1.0 ug/L
0.2 ug/L
0.5 ug/L
0.02 ug/L
1.1 ug/L
0.5 ug/L
ND (0.5)
3.9 ug/L
1.3 ug/L
aD (0.5)
Minimum %
Reduction
99.3
99.4
96.6
93.4
96.7
99.9
91.5
94.5
99
99.99
96.7
97.6
96.5
99.9
99
99.9
96
99.9
99.2
91.3
99.8
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 100 gallons (379 liters).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model PIKBI" The filter monitor system measures the amount of
water that passes through the filter and alerts you to replace the
filter.
Style 1 - When the filter indicator reads 10%, order a new filter.
When the indicator reads 0%, it is recommended that you
replace the filter.
Style 2 - When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended that you replace the filter.
Style 3 - When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter indicator
reads "REPLACE," it is recommended that you replace the filter.
Use replacement cartridge P1 RFKB1, part #9030.
2008 suggested retail price of $59.99 U.S.A./S71.99 Canada.
Prices are subject to change without notice.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Average %
Reduction
97.6
99.5
Average %
Reduction
99.3
99.3
96.6
95.3
96.7
99.9
92.8
94.5
99
99.99
98.5
97.6
96.6
99.9
99
99.9
96.4
99.9
99.8
96.2
99.8
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate 0.5 gpm (1.9 L/min) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
ttFibers greater than 10 um in length
€Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
30
Loading ...
Loading ...
Loading ...