CONNECTIONS ELECTRICAL
The power supply to the water heater must not be switched on until the
water heater is filled with water and a satisfactory megger reading is
obtained.
All electrical work and permanent wiring must be carried out by a qualified
person and in accordance with the Wiring Rules AS/NZS 3000 and all local
codes and regulatory authority requirements.
WATER HEATER
A water heater not fitted with a supply cord and plug must be directly connected
to a 240 V AC, 50 Hz mains power supply with an isolating switch installed at
the switchboard.
The power supply to a twin element model should be Off-Peak (overnight) to
the bottom heating unit and continuous to the top heating unit. The power
supply to a single element model can be either an Off-Peak (overnight),
Extended Off-Peak (overnight and day) or continuous electricity supply,
depending upon the size of the water heater. Check with the local electricity
supply authority as to their requirements. An Off-Peak (overnight) power supply
will provide the maximum financial savings. Discuss the power supply
requirements with the householder.
A flexible 20 mm conduit is required for the electrical cable to the water heater.
The conduit is to be connected to the unit with a 20 mm terminator. Connect
the power supply wires directly to the terminal block and earth tab connection,
ensuring there are no excess wire loops inside the front cover. The temperature
rating of the power supply wires insulation must suit this application.
A water heater fitted with a supply cord and plug must be plugged into a
switched 240 V AC, 50 Hz mains power outlet rated at 10 A. The GPO is
required to be weatherproof if installed outdoors.
THERMOSTAT SETTING
The thermostat on a Rheemglas and RheemPlus model is adjustable from
60°C to 70°C (60°C to 75°C on a 045, 050 model). The thermostat is adjusted
by turning the adjuster (Rheemglas / RheemPlus model) anticlockwise to
decrease the temperature setting and clockwise to increase the temperature
setting. Only adjust the thermostat setting on a Rheemglas and RheemPlus
model when the isolating switch is switched off at the switchboard. The top
thermostat on a twin element model is fixed at 60°C.
The thermostat of a RheemPlus model should not be set to less than 65°C.
This is to assist in the specified operation of the temperature limiting valve.