INSTALLAiTION INSTRUCTIONS 27
Connecfing Elecfric Dryers (conf.)
USA only
_WARNING
Connect the power cord to the terminal block.
Connect each power cord wire to the terminal block
screw that has the same colored wire. For example,
connect the black power cord wire to the terminal
block screw with the black wire. Failure to follow
these instructions may result in a short, overload,
fire or death.
Grounding through the neutral conductor is
prohibited for: (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and
(4) areas where local codes prohibit grounding
through the neutral conductor.
Three-wire connection for electric dryers: Direct wire
A 3-wire connection is NOT permitted on new
construction after January 1, 1996.
A ULqisted strain relief is required.
1
1. Remove 3/2 inches (8.9 cm) of the outer covering from
the wire. Strip 1 inch (2.5 cm) insulation from each
wire. Bend the ends of the three wires into a hook
shape.
1" (2,5 cm)
. Use UL-listed :}-wire #10 AWG-minimum copper
conductor cable.
, Allow at least S ft. (1.5 m) length to allow for removal
and reinstailation of the dryer.
3. Attach the two hot leads of the power cord to the
outer terminal block screws. Attach the neutral wire to
the center terminal block screw. Connect the external
ground (if required by local codes) to the green
ground screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover,
Neutral
Hot
(White)
(Black) |
Ground Hot
Screw _Red)
WhiteWire / _.__
from Dryer / _ _-a_M_,,_
harness/
External Ground "N \
Wire (If required
by local codes)
2. Remove the terminal block access cover on the upper
back of the dryer. Install a UL-iisted strain relief into
the power cord through-hole; then thread the power
cable prepared in Step 1 through the strain relief.
__ Terminal
Uk-Listed 3-Wire /
Power Cord