Monessen VFI33LPV

User Manual - Page 25

For VFI33LPV.

PDF File Manual, 44 pages, Read Online | Download pdf file

VFI33LPV photo
Loading ...
Loading ...
Loading ...
VFI33 Vent Free Gas Fireplace System
20307670
25
LOG PLACEMENT
Use only rock wool provided with log
set.
Do not add additional rock wool.
CAUTION
Figure 25 -
Place Rock Wool
LOG PLACEMENT
INSTALL 18" (F, R) BERKLEY OAK LOGS ON NATU-
RAL BLAZE BURNER (AVAILABLE FOR MONESSEN
SYSTEMS ONLY)
1. Place the #1 log (the “chunk”) on the grate bar right side
of the burner adjacent to the controls. Figure 26
Figure 27 -
Place Right Front Log #2
2. Place front right log (#2) on right pin located on burner
and right grate bar. Figure 27. Slide log #1 forward so
that it is tight against log #2.
ROCK WOOL PLACEMENT
Before installing logs, place rock wool in dime size pieces
evenly over small burner ports starting in the rear of the
burner going towards the front. Avoid placing rock wool on
slots on each side of rear burner and on large yellow ame
ports on front of burner. After covering small burner ports,
discard any excess rock wool. Figure 25
Figure 26 -
Place Ember Chunk Log #1
Ember Chunk
Log #1
Right Front
Log #2
Figure 28 -
Place Right Rear Log #3
Right Rear
Log #3
3. Place right rear log (#3) on pin located on rear support
bracket and rest left side of log on front right log. Figure
28.
Figure 29 -
Place Left Rear Log #4
4. Place left rear log (#4) on pin located on rear support
bracket on left side. Figure 29
Left Rear Log #4
Dime-sized
pieces of rock wool
Loading ...
Loading ...
Loading ...