Active – brown
Neutral –blue
WIRING DIAGRAM
STARTING YOUR
HEAT PUMP
WATER HEATER
In order to protect the tank against corrosion,
the water heater must remain switched on at all times.
The wires in the electric cable are crimped. If you need to cut them, remember to crimp
them again before connecting to the electric power supply.
Electric
panel
FOR TIME CLOCK CONTROL - TIME OF USE TARIFF:
240 volt supply with 2 amp protection connected to the black auxiliary wire and the time clock programmed
in accordance with the time of use tariff hours. Set HCHP parameter to ON, see page 15 setting the regulation.
FOR ACI PROTECTION:
The HPWH must remain connected to the permanent power supply at all times so that the operation of the
(ACI) anti-corrosion protection of the water heater is ensured.
For more information
Please refer to the «Electric connections» and «Getting started» chapters in this manual.
WIRING DIAGRAM
MAINTAINING YOUR
HEAT PUMP
WATER HEATER
1 Permanent power supply
2 Off-peak hours cable
3 Regulation
4 Incoming air sensor
5 Evaporator sensor
6 Pocket sensor
7 Anti-corrosion protection
8 1,800W steatite backup
9 Pocket
10 Mechanical safety device
11 Hot gas solenoid
12 Compressor condenser
13 Compressor
14 Low-speed condenser
15 Fan
16 Fan condenser
17 Safety pressure switch
18 Safety horn
19 Heat pump shells