GAS SUPPLY:
This appliance is suitable for use with Natural Gas or ULPG. (Check the “gas type”
sticker attached to the appliance).
For Natural Gas the gas supply must be regulated to obtain a pressure of 1 kPa with
the two semi-rapid (SR) burners operating.
For ULPG models connect the gas supply directly to the appliance test point adap-
tor (supplied with the conversion kit) and ensure that the supply pressure is regulat-
ed to 2.75 kPa.
Do NOT force the ”elbow“ rotation prior to loosening nut.
Do NOT over tighten the nut at the ”elbow“.
1. After connecting the gas supply, check the piping and connections for leaks using a
soap and water solution. The presence of bubbles indicates a leak, tighten or
replace connections as appropriate.
Warning: Do not use any naked flame to check for leaks.
2. The operation of the appliance MUST be tested before leaving.
3. Adjust the test point pressure or supply pressure to the value which is appropriate
for the gas type.
4. Turn on the appliance gas controls and light each burner. Check for a well defined
blue flame without any yellow tipping. If any abnormality is evident then check that
the burner cap is located properly and the injector nipple is aligned correctly.
Figure 5b
Figure 5a
Gas connection for
ULPG
Test point adaptor
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas inlet pipe
Test
point
Gas connection for
NATURAL GAS
Gas inlet pipe
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Test
point