Loading ...
Loading ...
Loading ...
10
CONVERSION PROCEDURE (to convert to Natural gas or to ULPG)
REPLACING THE INJECTORS
The conversion procedure must be carried out only by an authorised person.
This appliance is suitable for use with Natural gas or ULPG (check the “gas type” stick-
er attached to the appliance). The nominal gas consumption and injector size details
are provided in table at page 9.
To replace the injectors proceed as follows:
Remove pan supports and burners from the cooktop.
Using a spanner, remove the injector J (fig. 6, 7) and replace it with one
according to the gas type (see tables - page 9).
Affix to the appliance the warning label stating that the cooktop has been convert-
ed for use with ULPG (supplied with the ULPG conversion kit.).
A second ULPG conversion label should also be affixed to an adjacent surface
along with the duplicate data plate.
IMPORTANT
If the cooktop is suitable for use with Natural gas and must be converted for
use with ULPG, before connecting to gas main remove the appliance gas regu-
lator and replace with test point adaptor (see fig. 5a, 5b)
If the cooktop is suitable for use with ULPG and must be converted for use
with Natural gas, before connecting to the gas main remove the appliance test
point adaptor and replace with gas regulator (see figs. 5a, 5b).
NOTE:
Gas regulator and test point adaptor are supplied with the appliance (packed with
conversion kit)
The burners are designed so that regulation of primary air is not required.
Figure 6 Figure 7
J
J
Loading ...
Loading ...
Loading ...