35
Cavity Insert Instructions
The following instructions are intended for qualified
service personnel ONLY, and should only be done
when necessary.
In order to replace the ECO,thermistor or heating
element, remove the cavity insert crossbar by
following the instructions below:
Disconnect all power to unit before to
starting maintenance.
Remove the jacket access panel(s) and
insulation.
Rotate the crossbar up and down until it
breaks away from the remainder of the
cavity insert.
(See illustration to the left)
Discard the crossbar. It cannot and need not
be replaced.
Replace the ECO,thermistor and/or element
as necessary.
Replace the insulation, jacket access
panel(s) and plastic housing before turning
on the power to the water heater.
NOTICE: The cavity insert crossbar is
necessary for the manufacturing process only.
The removal of the crossbar will not interfere
with the operation of the water heater.
ECO
Reset