30
CTA Module Wiring
A separate branch circuit with copper conductors, overcurrent protective device
and suitable disconnecting means must be provided by a qualified electrician.
All wiring must conform to local codes or latest
edition of National Electrical Code ANSI/NFPA
70.
1. Use an appropriately sized wire nut to
connect the Red wire of the CTA module
box to the Red wire of the Water Heater
connection.
2. Use an appropriately sized wire nut to
connect the Black wire of the CTA module
box to the Black wire of the Water Heater
connection.
3. Use the ground screw to connect the green
wire of the CTA module box to ground.
4. The water heater is completely wired to the
junction box inside jacket at the top front of
the water heater.
*Note: A CTA2045 compliant Module
can be connected to the water heaters
top connector. Follow the instructions
from the CTA2045 Module supplier to
connect.
Water Heater Junction Box
Junction
Box Cover
Ground
Screw
Wire
Connections
CTA Adaptor
(Not applicable
for all models
Conduit
connector
Loading ...