Goodlevellingisessentialforcorrectclosureandsealing
ofthedoor.
Whentheapplianceiscorrectlylevelled,thedoorwillnot
catchorruboneithersideofthecabinet.
Leaveaspaceof2mmbetweenthetopofthedishwasher
andtheundersideofthekitchencounter.
Theheightoftherecesswherethedishwasheristobeinstalled
canvarybetween855mmand860mmfromtheoor(with
worktop)and825-830(withoutworktop)sincethedishwasheris
ttedwithadjustablefeet(max.10mm).Ifworktopisremoveda
llerpiecemayberequired.
Leaveaspaceof2mmbetweenthetopofthedishwasher
andtheundersideofthekitchencounter.
CAUTION
CAUTION
Check if the
dishwasher is levelled
600mm
855-860mm with worktop
825-830mm without worktop
IMPOR TANT
820mm
180mm
50mm
100mm
595mm
120mm
555mm edge of door
585mm centre of door
825mm min.
880mm max.
585mm
600mm
Do not install taps or
power points in this space
Gap on both sides
should be equal and no greater
than 3mm per side
If floor is not level, adjust
levelling legs to suit
600mm max -
300mm min
POWER SUPPLY
230/240V–10Amps
TAP CONNECTION
If cold-water pressure is
in excess of 800kPa, a
pressure-reducing valve
should be used.
Check for leaks.
INLET WATER SUPPLY
Water flow rate 10L/minute min
Water temperature 60
o
C max
Water pressure cold water:
800kPa max - 50kPa min
Water pressure hot water:
350kPa max - 50kPa min
Cold water recommended
The hose should not be
extended by more than
2 metres or water pump-out
problems may occur
There should be a minimum
2mm gap between the top of
the dishwasher and
underside of bench top
Fix drain hose max of
10mm below the top of
the dishwasher
Remove entire plastic
membrane from sink trap
spigot & fit drain hose to
spigot with clamp
DISHWASHER
POWER OUTLET
SINK
1000mm max

Fittheadhesivesteamprotectionontothefrontpartofthe
worktop,alongtheentirewidth.

Theinlethoseshouldbeinspectedevery12monthsfor
deteriorationandreplacedifnecessary.
Cold water connection
–Werecommendconnectiontoacoldwatersupply.
–Waterpressuresbetween50kPaand800kPaare
acceptable.
–Apressure-reducingvalvemustbettedifthecoldwater
supplyexceeds800kPa.(Referalsototheremarksinthe
sectionbelowconcerningwaterhammer.)
Water hammer
Quickactionhouseholdtapsandfastactingwatervalves
onappliancescancausewaterhammer.Thiscanresultin
veryhighwaterpressures.Highpressurecancausefailure
ofthepressurereducingvalve(wheretted),orthewater
valveinyourdishwasher.

600mm