Loading ...
Loading ...
Loading ...
17
OPERATIONS MANUAL
REFRIGERATED GRIDDLE STANDS
HINGE TENSION ADJUSTMENT
The self-closing doors on your unit have a spring-loaded hinge
cartridge concealed in the door (see Figure 7) with a hold-open
feature and a cushioned stop. When the door is fully opened
(115°) the hinge should be tensionfree. When the door is moved
between the open and closed position, the spring-loaded hinge
will automatically rotate the door toward the closed position. For
proper operation, self-closing doors must be installed with the
spring-loaded hinge mechanism set to apply tension in the
proper direction (see Figure 8).
To adjust spring tension, Open the door fully (115°) so it stays in
position when released. Remove the mounting screws securing
the cartridge bracket to the cabinet (see Figure 6). The bracket
should stay in position when released, but if it is moved or
bumped, it may snap into the closed position.
THE HINGE CARTRIDGE IS SPRING LOADED AND MAY
SNAP BACK ON FINGERS WHEN BRACKET IS LOOSE.
WEAR WORK GLOVES AND USE CAUTION WHEN
REMOVING MOUNTING SCREWS!!
Use a hinge cartridge bracket as a wrench by positioning it
upside down with the square hole over the square hub on the
spring mechanism (see Figure 7). Carefully turn the square hub
on the cartridge in the direction shown to tighten the spring.
The mechanism should snap to a neutral position. Remount the
hinge as shown and repeat the procedure described above until
the hinge snaps back when it is moved from the open-door posi-
tion towards the closed-door position.
For example, if the sensing device in the cabinet reads 38° and
the thermometer display reads 40°, press on the lower left cor-
ner twice so that “-2” appears on the display. After adjusting the
offset, press on the right center of the display again to exit cali-
bration mode. Wait 10 to 15 seconds for the cabinet temperature
to be displayed and recheck the calibration.
NOTE: The buttons need to be pressed without delay
between actions. Contact the factory with any questions.
DOOR ADJUSTMENT
All doors are aligned at the factory, however vibration during
transit may cause them to shift and adjustment may be neces-
sary. If a door requires realignment, carefully open the door
(90°) and loosen, but do not remove the mounting screws
securing both the top (see Figure 6) and bottom (see Figure
8) hinge brackets to the cabinet. Move the door to the desired
position by hand or by gently tapping on the edge with a rubber
mallet. Hold the door firmly in place and tighten all mounting
screws securely, above and below the door. Check alignment
and repeat adjustment if necessary.
FIGURE 7: Spring-Loaded Hinge Mounting















FIGURE 6: Hinge Adjustment












Press here to decrease temp.
Press here for
calibration modePress here to increase temp.