Removal and Installation
Initial Installation
The water filter is located in the upper right hand corner of the fresh food
compartment.
Remove sealing label from end of filter and insert into filter head.
Rotate gently clockwise until filter stops. Snap filter cover closed.
IMPORTANT:
After connecting the refrigerator to a water source, flush the water system. Use a
sturdy container to depress and hold the dispenser lever for five seconds, then
release it for five seconds. Repeat until water begins to flow. Once water begins
to flow, continue depressing and releasing the dispenser lever (five seconds on,
five seconds off) for an additional five minutes until a total of 4 gal. (15L) has been
dispensed. This will flush air from the filter and water dispensing system. Addi-
tional flushing may be required in some households. As air is cleared from the
system, water may spurt out of the dispenser.
Replacing Water Filter
Important: Air trapped in system may cause water and cartridge to eject. Always dispense
water for two minutes before removing the filter for any reason. Use caution when remov-
ing.
Turn filter counterclockwise until it releases from filter head.
Drain water from filter into sink, and dispose of filter in normal household trash.
Wipe up excess water in filter cover and continue with Initial Installation. The filter should be
changed at least every 6 months.
Important: Condition of water and amount used determines life span of water filter cartridge. If
water use is high, or if water is of poor quality, replacement may need to take place more often.
Replacement water filters are available through your local Viking Range Dealer. You may also
order filters by calling 1-888-845-4641 or online at vikingrange.com
The dispenser feature may be used without a water filter cartridge. If you choose this option, re-
place filter with blue bypass cap.
System Specification and Performance Data Sheet Refrigerator Water Filter
Cartridge Model RWFFR
Specifications
Service Flow Rate (Maximum)................................ 0.78 GPM
...............................................................................(2.9 L/min)
Rated Service Life RWFFR (750 gal. Max)..............750 gal. /2838 liters
Maximum Operating Temperature .......................100° F / 38° C
Minimum Pressure Requirement............................35 psi /241 kPA
Minimum Operating Temperature.........................33° F/1° C
Maximum Operating Pressure ...............................120 psi / 827 kPA
17
16
Water Filter
Standard No. 42: Aesthetic Effects
Parameter
USEPA
MCL
Influent
Challenge
Concentration
Influent
Average
Effluent
Average Maximum
%Reduction
Average Minimum
Min.
Required
Reduction
Chlorine __
2.0 mg/L + 10% 1.88 mg/L
<0.051363
mg/L
0.06 mg/L >97.26% 96.84% 50%
T & O __
__ __ __ __ __ __ __
Particulate** __
at least 10,000
particles/ml
5,700,000
#/ml
30,583 #/ml
69,000
#/ml
99.52% 98.94% 85%
Standard No. 53: Health Effects
Parameter
USEPA
MCL
Influent
Challenge
Concentration
Influent
Average
Effluent
Average Maximum
%Reduction
Average Minimum
Min.
Required
Reduction
Turbidity 1NTU** 11 + 1 NTU*** 10.7 NTU .031 NTU 0.49 NTU 97.09% 95.20% 0.5NTU
Cysts
99.5% Re-
duction
Minimum 50,000/L 166,500 #/L <1 #/L <1 #/L >99.99% >99.99% >99.95%
Asbestos
99% Reduc-
tion
10
7
10
8
fibers/L; fibers
>10 micrometers in
length
155 MF/L <1 MF/L <1 MF/L >99.99% >99.99% 99%
Lead at pH 6.5 0.015 mg/L 0.15 mg/L + 10% 0.153 mg/L <0.001 mg/L <0.001 mg/L >99.35% >99.29% 0.10 mg/L
Lead at pH 8.5 0.015 mg/L 0.15 mg/L + 10% 0.150 mg/L <0.001 mg/L <0.001 mg/L >99.33% >99.29% 0.10 mg/L
Mercury at pH 6.5 0.002 mg/L .006 mg/L + 10% 0.006 mg/L 0.0003 mg/L 0.0005 mg/L 95.70% 90.91% 0.002 mg/L
Mercury at pH 8.5 0.002 mg/L .006 mg/L + 10% 0.006 mg/L 0.0008 mg/L 0.0015 mg/L 86.22% 75.93% 0.002 mg/L
Atrazine 0.003 mg/L 0.009 mg/L + 10% 0.009 mg/L <0.002 mg/L 0.002 mg/L 76.99% 75.31% 0.003 mg/L
Benzene 0.005 mg/L 0.015 mg/L + 10% 0.014 mg/L 0.0006 mg/L 0.0011 mg/L 95.71% 92.14% 0.005 mg/L
Carbofuran 0.04 mg/L 0.08 mg/L + 10% 0.081 mg/L <0.001 mg/L <0.001 mg/L 98.74% 98.46% 0.04 mg/L
p-Dichlorobenzene 0.075 mg/L
0.225 mg/L + 10% 0.208 mg/L <0.0005 mg/L <0.0005 mg/L 99.76% 99.74% 0.075 mg/L
Lindane 0.0002 mg/L 0.002 mg/L + 10% 0.002 mg/L 0.000 mg/L <0.0001 mg/L 98.72% 96.50% 0.0002 mg/L
Toxaphene 0.003 mg/L 0.015 mg/L + 10% 0.015 mg/L <0.001 mg/L <0.001 mg/L 92.97% 91.67% 0.003 mg/L