Replacernent and Care of Filters
WARNING: To reduce the risk of shock I
or injury from moving parts, always t
l
unplug humidifier before removing or t
replacing any parts, t
CAUTiON: To help retard bacteria l
growth and keep maximum efficiency, I
the filters should be replaced at least I
once per season, or more often under I
hard water conditions. Use Sears rec- I
ommended replacement filter 42-14911. I
Ail filters may be rinsed in clear water only.
Take care not to damage paper. To replace
evaporative wicking filters in your Kenmore
Quiet Comfort Whole House humidifier, fol-
low the instructionsbelow.
1. Unplug humidifier and proceed to clean.
Before removing the filters, we recom-
mend moving the humidifier to an area
where floor coverings are not suscepti-
ble to water damage, i.e. kitchen or bath
areas.
2. Open the pivoting lid and remove water
bottles and set aside. Grasp the fan
assembly front center and rear center.
Lift off and set aside on a clean flat sur-
face. The filter housings are now acces-
sible.
3. Lift filter housing outof cabinet and place
where you may work on them comfort-
ably. With a soft, absorbent cloth remove
any remaining water or loose mineral
deposits not trapped inthe fitter from the
humidifier cabinet.
4. To open filter housing for easy access to
filters:
a. Deflect the two spring tabs on top of
filter housing. Lift top cover off of the
filter housing and set aside.
b. Remove the two filters and dispose
of properly. Clean internal parts of
humidifier per the "Cleaning of
Humidifier" section of your owner's
manual,
Pivoting Lid
Fan Assembly
Cabinet
Front of Humidiifer
Spring Tabs