IMPORTANT INFORMATION
IMPORTANT:
Gas Inspector's use.
INSTALLER:
Please leave these Installation
Instructions with the unit for the owner.
OWNER:
Please retain these instructions for future
reference.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70
PLEASE READ ENTIRE
INSTRUCTIONS
BEFORE PROCEEDING.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance
Do not touch any electrical switch
Do not use any phone in your building
Immediately call your gas supplier from a
neighbor’s
phone. Follow the gas supplier's in-
structions.
If you can not reach your gas supplier, call
the
fire department.
WARNING! Disconnect Power before installing.
Before turning power ON, be sure that all controls
are in the OFF position.
In the commonwealth of Massachusetts, gas
connection must be performed by a licensed
plumber or gas fitter.
Be sure the unit being installed is set up for the
type of gas supplied. The Gas rangetop shipped
from
the factory is set for Natural Gas or LP (Propane),
depending on the specific model ordered.
ENSURE THAT THE RANGETOP IS COMPATIBLE
WITH GAS SUPPLY AT THE INSTALLATION SITE
BEFORE
PROCEEDING FURTHER. Contact the
dealer if it
is not set for the proper gas supply available
at the installation site.
IMPORTANT!
A back guard must be utilized when
there is
less
than 12" horizontal clearance between
combustible materials and the back edge of the
rangetop. The Capital CULINARIAN SERIES Low Back
or
High Shelf must be ordered separately and installed
at the rear of the rangetop. For island installations
and
other installations with more than 12" clearance, our
stainless steel Island Trim is suitable to cover the
back guard mounting flanges.
ELECTRIC POWER SUPPLY
CGRT30, CGRT30 models
-
120 VAC, 60 HZ, 1 PH.,
20 Amp Circuit
C
GRT
36, C
GRT
36 models
-
120 VAC, 60 HZ, 1
PH.,
20 Amp Circuit
CGRT48, CGRT48 models
-
120 VAC, 60 HZ, 1 PH.,
20 Amp Circuit
CGSR60, CGMR60 Models
-
120 VAC, 60 HZ, 1 PH,
20 Amp Circuit.
STEP 1: UNPACKING, MOVING and PLACING the
RANGE
GAS SUPPLY
NATURAL GAS:
6
-
inch water column. (14.9mb)
Min., 8 inch (20mb) nominal
PROPANE GAS:
11
-
inch water column. (27.4m b),
14 inch (37mb) maximum
CAUTION: Proper equipment and adequate
manpower must be used in moving the range to
avoid damage to the unit or the floor. The unit is
heavy and rests on stainless steel legs.
It is strongly recommended that after removing the
packing, top grates,
and drip pan(s) to
facilitate
lifting and easier handling.
Remove the outer carton and packing materials
from the shipping base. All gas ranges are held to
the
skid by three (3) bolts. After removing the bolts
the
rangetop must be lifted and removed from the skid.
WARNING!
If the information in this manual is
not followed exactly, a fire or explosion
may
result causing property damage, personal
injury or death.
The appliance and its individual shutoff valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 5 psi (35 kPa).
The appliance must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 5 psi (35 kpa).
IMPORTANT!
Installation, electrical connections,
grounding and gas connections must comply with
all applicable codes. In the absence of local codes,
the unit should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA54
-
CURRENT ISSUE and National Electrical Code ANSI/
NFPA70
-
CURRENT ISSUE.
NOTE: Local building codes vary. Cabinet storage
above the unit should be avoided to prevent the
risk of accidental fire or burns.
IMPORTANT!
Installation must conformwith local codes.
IMPORTANT INSTALLATION INSTRUCTIONS
INTRODUCTION
Capital's CULINARIAN Series Gas Rangetops are
tested
and approved in accordance with ANSI
Z21.1.2005, CAN 1
-
1.1,M81
1995, Household Cook-
ing Appliances. It
is STRONGLY RECOMMENDED
that this appliance be
installed in conjunction with a suit-
able overhead CAPITAL
VENT HOODDue tothehighheat
output ofthisunit, particular
attention should be paid to the
hood and ductwork installation to ensure it meets local
building codes.