Removing the collected water
1. Pull out the bucket a little.
3. Pour the water out.
There are two ways to remove collected water.
1. Use the bucket
When the unit is off,if the bucket is full, the unit will
beep 8 times and the Full indicator light will flash, the
digital display shows P2.
When the unit is on, if the bucket is full, the compressor
turns offand the fan turns off after 30 seconds for drying
the water then the unit will beep 8 times and the Full
indicatorlight will flash, the digital display shows P2.
Slowly pull out the bucket. Grip the left and right
handles securely, and carefully pull out straight so
water does not spill. Do not put the bucket on thefloor
becausethe bottom of the bucket is uneven. Otherwise
the bucket will fall and cause the water to spill.
Pour out the water and reinstall the bucket.The bucket
must be in place and securely seated for the
dehumidifier to operate.
The machine will re-start when the bucket i
s restored
in i
ts correct position.
NOTES:
When you remove the bucket, do not touch any parts
inside of theunit. Doing so may damage the product.
Be sure to push the bucket gently all the way into the
unit. Banging the bucket against anything or failing to
push it in securely may cause the unit not to operate.
When you remove the bucket,if there is some water in
the unit it must be dried.
Fig.5
Fig.6
2. Continuous draining
Water can beautomatically emptied into afloor
Fig.8
Plastic cover
Drain hose
Adaptor
Fig.7
Drain hose
subassembly
Fig.9
Connector
Drain hose
Fig.10
Water hose
Female threadeGHQG
OPERATING THE UNIT
Ý
Ý
8mm ,not included w
i
th afemale threaded
end (I.D. ,not included.
Make sure the hose is secure so there are no leaks.
Direct the hose toward the drain,making sure that
there are no kinksthat will stop the warter flowing.
Place the end of the hose into the drain and make sure
the end of the hoseis level or down tolet the water flow
smoothly.
Place the bucket back in the unit and make sure
that it is located correctly.
Select the desiredhumidity setting and fan speed
on the unit for continuous draining to start.
the drain hoseisonto the adaptor A (See Fig.7,
placed in the bucket
Remove the plasticcover from the back drain outlet of
the unit and remove bucket,then insert
the drain hose
through the drain outlet of the unit and
securely press it
onto the connector on the front of the
unit.(See.Fig.9
Tighten the adaptorA and the unit by using two screws
(placed in the bucket
Install the female threaded end of the water hose
the adaptor A.(See.Fig.10then lead the
water hose to the floor drain ora suitable drainage
NOTE: When the continuous drain feature
is notbeing used,removethe drain hose
from the outlet.
(
I.D.
26mm
opening.
Make sure it is not pointing upwards.
QRWLQFOXGHG
8
,
A
Make sure
d
2. Hold both sides of the bucket
with even strength, and pull it
out from the unit.