Performance Data Sheet
SmartWatarFdtretioaSystem
GWF/ HWFCartridge
Thissystemhas beentestedaccordingto NSF/ANSI 42,/53for reductionofthesubstanceslisted balow.
Theconcentrationofthe indicated substancesin water enteringthe systemwas reducedto a concentration
lessthanor equal tothepermissiblelimit for water leavingtha system,as specifiedin NSF/ANSI42J53.*
(100%safety factorsbuiltin for unmeteredusage)
Parameter
Chlorine
T&O
Particulate**
USEPA
MGL
Standard No. 42: Aesthetic Effects
Influent
(_tallenge Concentration
2.0 mg/L ± 10%
atleast I0,000 parficles/mL
Efl]tlent
Average Max±reran
0.02ppm 0.05 ppm
3,978 7,800
Standard No. 53: Health Effects
Parameter
Turbidity
cysts
Lead at pH 6.5
Lead at pH 8.5
Lindane
Atrazine
2,4-D
Asbesto_
USEPA
Mgl
1 NTU***
99.95% Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 ppm
0.100 ppm
90%
Influent
Challenge Concentration
11 £ 1 NTU***
Minimum 50,000 L
0.15 mg/L± 10%
0.15 mg/L± 10%
0.002 rag/L_+ 10%
0.009 rng/L + 10%
0.210 rag/L_+ 10%
10" to l& fibers/L;
fibers greater than
10 micrometers in length
Efllttmat
Average Maximum
0.07 NTU 0.1 NTU
26 55
l ppb 1 ppb
1.8 ppb 4.3 ppb
0.0_05 ppm 0.00005 ppm
0.002 ppm 0.003 ppm
0.042 ppm 0.090 ppm
0.32 MFL/ml 1.2 MKL/ml
* Testedusinga flew rate of0.5gpm;pressureof 60psig; pH of Z5_+0,5;temp.ofZO°_+Z5°C
** Measurementin Particles/mLParticlesusedwere0.5-1 microns
"** N[U=Nephe!ometricTurbidityunits
% Reduction
Average _tm_tnn
98.90% 97.37%
m
98.00% 96.10%
%Reduction
Average Minimum
99.71% 99.59%
99.97% 99.95%
99.37% 99.37%
98.8% 97.13%
91.93% 91.93%
76.19% 64.28%
84.89% 67.63%
99.95% 99.82%
M_ a,,q_a*d
Reduction
> 50%
_85%
m,qtthtd
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
0.07 mg/L
99%
Operating Specifications
Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light; up
to one year for models with a replacement filter indicator light
Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
Temperature: 33-100°F (0.6-38°C)
Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 3 minutes to purge out trapped air.
Replace cartridge when flow becomes too slow.
Special Notices
Installation instructions, parts and service availability,, and standard warranty are included with the product when shipped.
This th'inkiug water system must be inair tained according to manufacturer s instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances relnoved or reduced by this water treatment system are not necessarily in your
water.
Check for compliance with the state and local laws and regmlations.
Note that while the testing was perfornled under standard laborato W conditions, actual performance may vary. Systems
must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Sxstem li'sted and Ce] dried bv NSF lntm national against ANSIiNSF Standmx142 & 53 lot
the leduclion of:
Standard No. 42: Aesthetic Effects
Chemical 1nit
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtl'adon Unit
Palticulate Reduction, Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrazine Reduction
Lindane and 2,4-D Reduction
Me€ hanica[ Filtration Unit
Ttu bidit'_ Reduction
Cyst and Asbestos Reduction
Manutactured fol: General Electric Company, Louisville. KY 40225