Verona 879541 2-Piece Kitchen Package with VEFSGE304PSS 30 Inch Freestanding Dual Fuel Range and Chefs Pak in Stainless Steel

User Manual - Page 20

For 879541.

PDF File Manual, 24 pages, Read Online | Download pdf file

879541 photo
Loading ...
Loading ...
Loading ...
20
electrical connection
3
WARNING
TO AVOID ELECTRICAL SHOCK HA-
ZARD, BEFORE INSTALLING THE
APPLIANCE, SWITCH POWER OFF
AT THE SERVICE PANEL AND LOCK
THE PANEL TO PREVENT THE PO-
WER FROM BEING SWITCHED ON
ACCIDENTALLY.
ELECTRICAL REQUIREMENTS
• Thisappliancemustbeproperlyinstalledandgroundedbyaqualiedtechnicianin
accordancewiththeNationalElectricalCodeANSI/NFPANo.70(latestedition)and
localelectricalcoderequirements.
• Thisappliancemaybeconnectedbymeansofpermanent“HardWiring”or“Power
SupplyCordkit”.
• Powersupplycordisnotsupplied,butitisavailablethroughyourlocalelectricsup-
plyhouse.
• Useonly3-conductoror4-conductorCSA/ULlistedrangecordratedat30ampswith
250Vminimumandprovidedwithringterminals.Thesecordsshouldbeprovided
withstrainrelieforconduitconnector.
Warning: Framegroundedthroughneutrallead.Ifusedin,
Newbranch-circuitinstallations(1996NEC),
Mobilehomes,
Recreationalvehicles,or
Inanareawherelocalcodesprohibitgroundingthroughneutral,usea4con-
ductorcordorconduit.
• The range must be connected to the proper electrical voltage and frequency as
speciedontheratingplate.
• Therangecanbeconnecteddirectlytothefuseddisconnect(orcircuitbreakerbox)
throughexible,counduitwithcopperoraluminiumwiring(withgroundingwire).
Allowtwotothreefeetofslackinthelinesothatitcanbemovedifservicingisever
necessary.
ELECTRICAL CONNECTION WITH POWER CORD
Usea3-wirepowersupplycordkitratedfor30amps-240-208/120voltswithclosedloop
terminalsandmarkedforusewithranges.
Wherelocalcodesdonotpermitgroundingthroughneutral,usea4-wirepowersupply
cord.
TheCSA/ULlistedcordmustbesecuredtotherangewithasuitablestrainreliefbra-
cket.
Theelectricalconnectionismadeattheterminalblock,whichislocatedbehindtheac-
cessdooronthebackoftherange.
ELECTRICAL CONNECTION WITH CONDUIT
Use1/2”(1.3cm)tradesizeCSA/ULlistedconduitwithaconduitclamp,16AWG/600
voltcopperconductorcoloredredforline1andblack forline2and16AWG/600volt
copperconductor(or14AWG/600voltcopperconductorifgrounding throughneutral)
coloredwhiteforneutralwithclosedloopterminalsmarkedforusewithranges.
Wherelocalcodesdonotpermitgroundingthroughneutral,useagreen14AWGcopper
conductorasdirectedinthe4-wireconnectordirections.
Theconduitmustbesecuredtotherangewiththestrainreliefbracket.
Theelectricalconnectionismadeattheterminalblock,whichislocatedbehindtheac-
cessdooronthebackoftherange.
Loading ...
Loading ...
Loading ...