PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
9.4
Remote Blowers
REMP3, REMP16
15"
(381mm) Min.
(Either Side)
15"
(381mm)
Minimum
Return Wall
(Either Side)
Exterior
Grade Level
Arc of
Rotation
Arc of
Minimum Clearance
to Obstructions
Air
Discharge
REMP CHASSIS ROTATION
(Exterior Wall View)
Model No.
Dedicated Circuit
Required
Maximum Duct
Length
Total Connected
Load Blower Rating
Approximate
Shipping Weight Finish
REMP3
Refer to Ventilator
Specifications
Refer to Duct
Planning
Specifications
0.05kW (4A) 1000 CFM 40 lbs.
Galvanized
(may be painted)
REMP16 0.03kW (3A) 1600 CFM 72 lbs.
Roof Curb
REMP WITH ROOF CURB
(Top & Side Views)
25 1/2"
(648mm)
2"
(51mm)
19"
(483mm)
23 1/4"
(591mm)
6"
(152mm)
2"
(51mm)
33 1/2"
(851mm)
2"
(51mm)
26"
(660mm)
30 1/2"
(776mm)
6"
(152mm)
2"
(51mm)
REMP3
ROOF CURB DIMENSIONS
NOTE:
1. The REMP chassis may be rotated to clear
obstructions. 15” (381mm) min. clearance must
be maintained from the air discharge to any
obstruction. When mounting in a horizontal
position, shield the REMP to protect from possible
water collection in the chassis. Maintain a
minimum down slope of 1/4” (6mm) per foot for
evacuation of water.
2. When the REMP is installed on to a flat (less than a
1:12 pitch) roof, a roof curb is required.
REMP16
ROOF CURB DIMENSIONS