23
Flexible Connections: if the unit is to be installed
with exible couplings and/or quick-disconnect
ttings, the installer must use a heavy-duty AGA
design-certied exible connector or at least1/2”
(1.3 cm) ID NPT (with suitable strainreliefs) in
compliance with ANSI Z21.41and Z21.69.
G - area for gas connection
E - area for electric connection
In Canada: CAN 1-6, 10-88 metal connectors for
gas appliances and CAN 1-6.9 M79 quick disconnect
devices for use with gas fuel.
In Massachusetts:This appliance must be installed
with a 36” (3-foot) long exible gas connector.
GAS CONVERSION WARNING!
Before carrying out this operation, disconnect the
appliance from gas and electricity. Gas conversion
shall be conducted by a factory-trained professional.
Call the customer service hotline to identify a
factory-trained professional near your home. The gas
conversion procedure for this range includes 6 steps:
1. Pressure regulator
2. Surface burners
3. Main oven burner
4. Broiler burner
5. Visual checks prior to closure of oven bottom panel
6. Adjustment of minimum setting.
The conversion is not completed if all 6 steps have
not been concluded properly. Before performing
the gas conversion, locate the package containing
the replacement nozzle shipped with every range.
IMPORTANT: each nozzle has a number
indicating its ow diameter printed on the body.
Consult the table on “Specications Technical data
“paragraph for matching nozzles to burners. Save
the nozzles removed from the range for future use.
STEP1:PRESSURE REGULATOR
The pressure regulator supplied with the appliance
is a convertible type pressure regulator for use
with Natural Gas at a nominal outlet pressure of
4” w.c. or LP gas at a nominal outlet pressure of
11” w.c. and it is pre arranged from the factory to
operate with one of these gas/pressure as indicated
in the labels afxed on the appliance, package and
Instruction booklet.
To convert the regulator for use with other liquid
propane LP gas:
1. Unscrew by hand the upper
cap of the regulator, remove the
white plastic attachment from
the cap, reverse its direction
and screw it again rmly against
the cap. The white plastic
attachment must be turned as
follow for NATURAL GAS and
as reversed for LP/PROPANE
GAS
2. Screw by hand the metal cap
in the original position on the
regulator.
LP/PROPANE GAS
Gas Requirements
NATURAL GAS