Majestic RUBY35IL Ruby Series Direct Vent Liquid Propane Fireplace

User Manual - Page 17

For RUBY35IL.

PDF File Manual, 31 pages, Download pdf file

Loading ...
Loading ...
Loading ...
17
Majestic • RUBY25IN, RUBY25IL, RUBY30IN, RUBY30IL, RUBY35IN, RUBY35IL Owner’s Manual • 2542-981 Rev. D • 7/19
Removing Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
DO NOT strike, slam or scratch glass.
DO NOT operate replace with glass removed, cracked,
broken, or scratched.
Replace as a complete assembly.
The glass assembly fastens to the replace in four
places. The four fastening mechanisms are spring-
loaded glass latches. An example of the glass latch is
shown in Figure 4.2.
To release glass assembly, use the supplied multi-
purpose tool. See Figure 4.1. While supporting the
glass assembly, pull the two bottom spring-loaded
latches forward and allow them to retract away from the
glass assembly. Tilt the bottom of the glass assembly
outward until the top latches disengage.
Clean glass with a non-abrasive commercially available
cleaner.
- Light deposits: Use a soft cloth with soap and water.
- Heavy deposits: Use commercial fireplace glass
cleaner (consult with your dealer).
Figure 4.2 Fixed Glass Assembly
Figure 4.1 Multi-Purpose Tool
Replacing Fixed Glass Assembly
Verify Glass Seal Plate is properly installed. See Figure
4.3.
WARNING! Glass seal plate must be properly installed.
Risk of elevated component temps and carbon monox-
ide exposure.
• Tilt the top of the glass assembly toward replace and
slide glass assembly upward to engage top latches.
Verify top latches are fully engaged and then fasten the
two bottom latches using the supplied mulit-purpose tool.
Reinstall door or decorative front.
GLASS CLIPS
Figure 4.3 Glass Seal Plate
GLASS SEAL PLATE
Loading ...
Loading ...
Loading ...