Maytag MGDB200VQ0 dryer

User Manual - Page 8

For MGDB200VQ0.

PDF File Manual, 56 pages, Read Online | Download pdf file

MGDB200VQ0 photo
Loading ...
Loading ...
Loading ...
The location should be easy to reach for opening and dosing.
A C E
B D
A. _/t#' flexible gas connector
B. _/J pipe to flare adapter fitting
C. J/_" NPT minimum p/ugged tapping
D. _/J" NPT gas supp/y fine
E. Gas shutoff va/ve
Gas supply connection requirements
Use an e[bow and a 3/8H flare x @/8 u NPT adapter fitting between the f[exib[e gas connector
and the dryer gas pipe, as needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFI.ON "_*tape.
This dryer must be connected to the gas supply line with a listed flexible gas connector
that complies with the standard for connectors for gas appliances, ANSI Z21.24 or
CSA 6.10.
Burner Input Requirements:
Elevations above 10,000 ft (3,048 m):
When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown
on the model/serial number plate is required for each 1,000 ft (305 m) increase in
elevation.
Gas Supply Pressure Testing
The dryer must be disconnected from the gas supply piping system during pressure testing
at pressures greater than _/_psi.
Dryer Gas Pipe
The gas pipe that comes out through the rear of your dryer has a 3/sll male pipe thread.
(1.9 cm)
A. ;/8" NPT dryer pipe
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, or a
concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure exhaust hood is not plugged
with [int.
Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.
Review Vent system chart. Modify existing vent system if necessary to achieve the best
drying performance.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
t®TEF[ ON is a registered trademark of E.[. Du Pont De Nemours and Company.
8
Loading ...
Loading ...