Loading ...
Loading ...
You
will
need:
@
A
water
heater
set
to
120°
F
(49°
C).
@
A
grounded
electrical
outlet
located
within
4
ft.
(0.9
m)
of
power
cord
on
back
of
washer.
@
Hot
and
cold
water
faucets
located
within
3
ft.
(0.9
m)
of
hot
and
cold
water
fill
valves
on
washer,
and
water
pressure
of
5-100
psi
(84.5-690
kPa).
@
A level
floor
with
maximum
slope
of
1"
(25
mm)
under
entire
washer.
Installing
on
carpet
is
not
recommended.
@
Floor
must support washer’s
total
weight
(with
water
and
load)
of
315
Ibs
(143
kgs).
IMPORTANT:
Do
not
install,
store,
or
operate
washer
where
it
will
be
exposed
to
weather
or
in
temperatures
below
32°
F
(0° C).
Water
remaining
in
washer
after
use
may
cause
damage
in
low
temperatures.
See
“Washer
Care”
in
your
“Use
and
Care
Guide”.
Proper
installation
is
your
responsibility.
Recessed
area
or
closet
installation
"
48
in?
14
Log
(356
mm)
banat
°
(310
cm)
=
ie
|__
19"
I
penne
oO.
[|
(483
mm)
Ra
@
24
in?
(
of
'
(155
cm?)
102
mm
1
|
kK
'
.
———
o"
_
el
(25
mm)
3"
(Oo
mm)
(76
mm)
Dimensions
show
recommended
spacing
allowed,
except
for
closet
door
ventilation
openings
which
are
minimum
required.
Consider
allowing
more
space
for
ease
of
installation
and
servicing,
spacing
for
companion
appliances
and
clearances
for
walls,
doors,
and
floor
moldings.
Add
spacing
of 1"
(25
mm)
on
all
sides
of
washer
to
reduce
noise
transfer.
If
a
closet
door
or
louvered
door
is
installed,
top
and
bottom
air
openings
in
door
are
required.
DRAIN
SYSTEM
Drain
system
can
be
installed
using
a
floor
drain,
wall
standpipe,
floor
standpipe,
or
laundry
tub.
Select
method
you
need.
IMPORTANT:
To
avoid
siphoning,
no
more
than
4.5"
(113
mm)
of
drain
hose
should
be
inside
standpipe
or
below
the
top
of
wash
tub.
Secure
drain
hose
with
removable
tie
strap
(A).
Floor
standpipe
drain
system
Minimum
diameter
for
a
standpipe
drain:
2"
(61
mm).
Minimum
carry-away
capacity:
17
gal.
(64
L)
per
minute.
Some
standpipes
may
require
a
Standpipe
Adapter
Kit
and
additional
drain
hose
that
may
be
purchased
separately.
See
“Tools
and
Parts”.
Top
of
standpipe
must
be
at
least
39"
(991
mm)
high;
install
no
higher
than
96"
(2.4
m)
from
bottom
of
washer.
Installations
higher
than
96"
(2.4
m)
require
a
sump
pump
system.
Wall
standpipe
drain
system
4.5"
(113
Sh
See
requirements
for
floor
standpipe
drain
system.
Floor
drain
system
Floor
drain
system
requires
a
Siphon
Break
Kit
and
additional
drain
hose
that
may
be
purchased
separately.
See
“Tools
and
Parts”.
Minimum
siphon
break:
28"
(711
mm)
from
bottom
of
washer.
(Additional
hoses
might
be
needed.)
Laundry
tub
drain
system
Minimum
capacity:
20
gal.
(76
L).
Top
of
laundry
tub
must
be
at
least
39"
(991
mm)
above
floor;
install
no
higher
than
96"
(2.4
m)
from
bottom
of
washer.
Loading ...