Gas supply line
Shutoff valve
“open” position
To cooktop
2
gasconnection
2.PressureRegulator:
a. Allheavyduty,commercialtypecookingequipmentmusthaveapressureregulator
ontheincomingservicelineforsafeandefcientoperation,sinceservicepressure
mayuctuatewithlocaldemand.
Beforeinstallingtheregulatormountthe3/8”NPT(conical)maleconnectortothe
regulator(seepicture2.2c).
Gasketsuppliedhastobeplacedbetween3/8”NPT(conical)connector/extension
pipemalepipefitting(seepicture2.2d).
Theregulatorsuppliedwiththiscooktopmustbeinstalledbeforeanygasconnections
aremade.
Usesuppliedpressureregulatoronly.
Explosion Hazard
Use a new CSA or UL approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas connec-
tions.
If connected to LP, have a quali-
fied person make sure gas pres-
sure does not exceed 14" water
column.
Examples of a qualified person
include licensed heating per-
sonnel, authorized gas compa-
ny personnel, and authorized
service personnel.
Failure to do so can result in
death, explosion, or fire.
Fig. 2.1
Allgasconnectionsmustbemadeaccordingtonationalandlocalcodes.Thisgassupply
(service)linemustbethesamesizeorgreaterthantheinletlineoftheappliance.Sealant
onallpipejointsmustberesistanttotheactionofLP/Propanegas.
ThecooktopisequippedfortheusewithNATURALgas.Itisdesign-certiedbyCSA
InternationalforNATURALandL.P.gaseswithappropriateconversion.
Themodel/serialratingplate,locatedontheundersideoftheburnerbox,hasinformation
onthetypeofgasthatcanbeused.Ifthisinformationdoesnotagreewiththetypeof
gasavailable, check with the localgassupplier. Seepage from14 to15forL.P.gas
conversioninstructions.
1. Manual Shut-off Valve(g:2.1):
Amanualshut-offvalvemustbeinstalledinanaccessiblelocationinthegaslineexternal
tothe appliance forthe purposeof turning on orshuttingoffgas to the appliance(In
MassachusettssuchshutoffdevicesshouldbeapprovedbytheBoardofStateExaminers
ofPlumbers&GasFitters).
Thisvalveshouldbelocatedinthesameroomasthecooktopandshouldbeinalocation
thatallowseaseofopeningandclosing(inapositionwhereitcanbereachedquicklyin
theeventofanemergency).
Donotblockaccesstotheshutoffvalve.Thevalveisforturningonorshuttingoffgas
totheappliance.