1177669 Klimaire 2 Zone Mini Split System with 27000 BTU, Two KDIR12-H2 12K Indoor Ceiling Recessed Ducted Units and An Outdoor Unit in White

User Manual - Page 28

For 1177669.

PDF File Manual, 40 pages, Read Online | Download pdf file

1177669 photo
Loading ...
Loading ...
Loading ...
27
INSTALLATION INSTRUCTIONS
When the declivity of the drain pipe downwards
is over 1/100, there should not be any winding.
The total length of the drain pipe when pulled
out traversely shall not exceed 20m, when the
pipe is over long, a prop stand must be installed
to prevent winding.
Refer to the figures on the right for the
installation of the pipes.
1.5m~2m
Insulating
material
Downward declivity
lower than 1/100
Bend
S shape
VP30
Downward declivity
lower than 1/100
Put as deep as possible
(about 10cm)
Fig.50-9
Fig.50-10
Drainage test
Check whether the drain pipe is
unhindered.
New built house should have this test
done before paving the ceiling.
5.6 Wiring(Console)
CAUTION
The appliance shall be installed in accordance
with national wiring regualtions.
The air conditioner should use separate power
supply with rated voltage.
The external power supply to the air conditioner
should have ground wiring, which is linked to the
ground wiring of the indoor and outdoor unit.
The wiring work should be done by qualified
persons according to circuit drawing.
An all-pole disconnection device which has at
least 3mm separation distance in all pole and
a residual current device(RCD)with the rating
of above 10mA shall be incorporated in the fixed
wiring according to the national rule.
Be sure to locate the power wiring and the
signal wring well to avoid cross-disturbance.
Do not turn on the power until you have
checked carefully after wiring.
5.6.1 Connect the cable
The installation bearer of sensing
device rotated to another side, and then
takes off cover of electrical box. (Take
off the electrical box if the capacity is
18000btu/h as well as using network
function.) (Refer to Fig.50-10)
Installation bearer
of sensing device
All the pictures in this manual are for
explanation purpose only. They may be
slightly different from the air conditioner
you purchased(depend on model). The
actual shape shall prevail.
NOTE:
Loading ...
Loading ...
Loading ...