UVIOOA ULTRAVIOLET SYSTEM
9. Reconnect power to your UV System.
10. Verify that your ultraviolet bulbs are operating by viewing only through the tamp
light indicator on the lamp handle. Never look directly at your bulb while it is
illuminated.
11. Reconnect power to your heating and cooling system.
Bulb Replacement
Annual replacement of the bulb in your ultraviolet lamp is required to maintain
effectiveness.
1. Obtain the correct replacement bulb/handle assembly or replacement bulb for
your unit. See Table 1.
Table 1. Select a Replacement Bulb/Handle Assembly or Replacement Bulb.
Replacement Bulb/ SnapLamp TM
Unit Description Handle Assembly Replacement Bulb
UV100A1000 UC100A1005 UC18W1004
Air Treatment System
UV100A1018 UC100A1054 UC36W1006
Air Treatment System (two needed) (two needed)
UV100A1059 UC100A1054 UC36W1006
Surface Treatment System
UV100A2008 UC100A1054 UC36W1006
Surface Treatment System
2. Disconnect the power to your heating and cooling system.
3. Unplug or turn off power to your UV System and allow lamps to cool for at least
15 minutes.
4. Rotate the lamp handle counterclockwise and gently pull the lamp handle to
remove the bulb. See Fig. 5.
69-13814 10