INSTALLATION 19
Connecting the Water Line
Before You Begin
This water line installation is not covered by the refrigerator
warranty. Follow these instructions carefully to minimize the
risk of expensive water damage.
Water hammer (water banging in the pipes) in house plumbing
can cause damage to refrigerator parts and can lead to water
leakage or flooding. Call a qualified plumber to correct water
hammer before installing the water supply line to the refrigera-
tor.
CAUTION
If you use your refrigerator before connecting the
water line, make sure the icemaker power switch is in
the OFF (0) position.
CAUTION
install the icemaker tubing in areas where
Water Pressure
A cold water supply. The water pressure must be between 20
and 120 psi on models without a water filter and between 40
and 120 psi on models with a water filter.
If a reverse osmosis water filtration system is connected to
your cold water supply, this water line installation is not covered
by the refrigerator warranty. Follow the following instructions
carefully to minimize the risk of expensive water damage.
If a reverse osmosis water filtration system is connected to
your cold water supply, the water pressure to the reverse os-
mosis system needs to be a minimum of 40 to 60 psi (2.8 kgf/
cm 2 - 4.2 kgf/cm 2, less than 2.0-3.0 sec. to fill a cup of 7 oz
capacity).
U-Z_ CAUTION
_A(ear eye protection during installation to prevent |
If the water pressure from the reverse osmosis system is less
than 21 psi or 1.5 kgf/cm 2 (takes more than 4.0 sec to fill a cup
of 7 oz capacity):
Check to see if the sediment filter in the reverse osmosis
system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to
refill after heavy usage.
If the issue concerning water pressure from reverse
osmosis remains, call a licensed, qualified plumber.
All installations must be in accordance with local plumb-
ing code requirements.
What You Will Need
Copper Tubing,1Ain. outer diameter, to connect the re-
frigerator to the water supply. Be sure both ends of the
tubing are cut square.
To determine how much tubing you
need: measure the distance from the
water valve on the back of the refrig-
erator to the water supply pipe. Then,
add 8 feet (2.4 m). Be sure there is sufficient extra tubing
(about 8 feet [2.4 m] coiled into 3 turns of about 10 in. [25
cm] diameter) to allow the refrigerator to move out from
the wall after installation.
Power drill.
½ in. or adjustable wrench.
Flat blade and Phillips head screw-
drivers.
Two I/4 in. outer diameter compres-
sion nuts and 2 ferrules (sleeves)
to connect the copper tubing to
the shutoff valve and the refrig-
erator water valve.
If your existing copper water line has a flared fitting at the
end, you will need an adapter (available at plumbing supply
stores) to connect the water
line to the refrigerator OR you _f/f "_'_
can cut off the flared fitting with/ ,\ \_ /))
a tube cutter and then use a
compression fitting.
Shutoff valve to connect to the cold water line. The shutoff
valve should have a water inlet with a minimum inside
diameter of 5/32 in. at the point of connection to the
COLD WATER LINE. Saddle-type
shutoff valves are included in
many water supply kits. Before
purchasing, make sure a saddle-
type valve complies with your
local plumbing codes.
,-_ NOTE
A self piercing saddle type water valve should not be
used.
Loading ...
Loading ...
Loading ...