Installation
*INSTALLATION*
43
Electrical connection
Installation, maintenance or
repair work by unqualified persons
could be extremely dangerous. The
manufacturer cannot be held liable
for unauthorised work.
All electrical work should only be
undertaken by a suitably qualified
and competent electrician in strict
accordance with current national and
local safety and building code
regulations (BS7671 in the UK).
This cooker hood must only be
connected to a properly installed power
supply.
The electrical system must comply with
VDE0100 (BS 7671 in the UK).
For increased safety you should protect
the appliance with a suitable Residual
Current Device with a current trip of
30mA.
A suitable means of disconnection must
be provided on site for each pole.
Suitable means of disconnection
include switches with an all-pole
contact gap of at least 3mm. These
include circuit breakers, fuses and
contactors (EN60335).
The relevant connection data can be
found on the data plate (see “After
sales/Warranty”). Ensure that this data
matches the voltage and frequency of
your household power supply.
If a flexible connection cable is being
used to connect the appliance to the
power supply, the cross-sectional area
of the individual leads must be between
0.75mm² and 1.5mm².
The strain relief must be used to ensure
problem-free connection.