Installation Instructions (cont'd)
Water Piping
AWARNING
HOTTER WATERCAN SCALD:.Water heatersare intendedto
producehotwater. Water heated to a temperature whichwill
satisfyclotheswashing,dishwashing,and other sanitizingneeds
canscaldand permanently injureyouuponcon__.ct.Some peo-
pieare mote likelyto be permanentlyinjuredbyhot water than
othor_Theseincludethe elderly,children,the infirm,or physicad-
ly/meotallyhandicapped.Ifanyoneusinghotwater in yourhome
fitsinto oneofthasegroupsor ifthere isa IocaJcodeor statelaw
requiring a certaintemperaturewater at the hotwater ta_ than
youmusttakespecialprecaution_In additionto usingthe lowest
possibletemperature settingthat satisfiesyour hot water needs,
ameanssuchasa mixingvalve,shouldbe usedat the hot water
tapsusudby thesepeople or at the water beater. M_ng valves
are availableat plumbingsupplyor hardwarestore_ Followman-
ufacturers instructionsfor installation of the valves.Before
changing the factory setting on the thermostat, read the
'q'emperatureRnguladon"sectioninthis manual.
AWARNING I
This water heater shall not be connected to any I
heating systems or component(s) used with a non-
potab e water heating app ante.
Look at the top cover of the water heater. The cold water
inlet is markedcold. Put two or three turns of teflon tape
around the threaded end of the threaded-to-sweat coupling
and around bothends of the _A"threaded nipple. Usingflexi-
ble connectors, connect the cold water pipe to the coldwater
inlet of the waterheater.
NOTE4This water heater is super insulated to minimize
heat loss from the tank. Further reduction in heat loss
can be accomplished by insulating the hot water lines
from the water heater.
INSTALLATION COMPLETED USING
SEARS INSTALLATION KIT
SHUTOFF
FLEXIBLEWATER
CONNECTORS
H_T OUTLET l _ _['--
COLD INLET
TO HOUSE WATER LINE
THREADEDTO
SWEATCOUPLING THREADEDTO
SWEAT COUPLING
AWARNING
Toxicchemic=Issuch as used for treatment of boilers]
or non-potable water heating appliances shall never
be introduced into a potable water heating system.
NIPPLE NIPPLE
If a water heater is installed in a dosed water supply system;
such as one having a back-flow preventer, check valve, water
meter with a check valve, etc.., in the cold water supply; means
shall be provided to control thermal expansion. Contact the
local utility or local Sears Service Center on how to control this
situation.
NOTE: To protect against untimely corrosion of hot and
cold water fittings, it is strongly recommended that all-elec-
tric unions or couplings be installed on this water heater
wfien connected to copper pipe.
The illustration shows the attachment of the water piping to the
water heater. The water heater is equipped with '/4 water
connections.
NOTE: If using copper tubing, solder tubing to an adapter
before attaching the adapter to the cold water inlet connec-
tion. Do not solder the cold water supply llne directlyto the
cold water inlet. It will harm the dip tube and damage the
tank.
Lookat the top coverof the water heater.The water oudet is
marked hot. Put two or three turns of teflon tape around the
threaded end of the threaded-to-sweat coupling and around
both ends of the 3A"threaded nipple. Using flexible connec-
tors, connect the hot water pipe to the hot water outlet on
the water heater.
'-,,I--TEMPERATURE.
PRESSURE
RELIEFVALVE
-- DISCHARGE
PIPE (Do notcap
or plus)
i" AIR GAP
FLOOR DRAIN
II