7
7
MAINTENANCE
Grease filters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
The filters must be cleaned every 2 months of operation, or
more frequently for particularly heavy usage, and can be
washed in a dishwasher.
Remove the filters one at a time by pushing them towards the
back of the group and pulling down at the same time.
Wash the filters, taking care not to bend them. Allow them to
dry before refitting.
When refitting the filters, make sure that the handle is visible
on the outside.
Charcoal filter (recycling version)
REPLACING THE CHARCOAL FILTER
Charcoal filter cannot be regenerated or washed. It has to be
substituted at least every 4 months or even more frequently
when the use of the hood is particularly intensive.
Remove the filter support pulling downwards the side levers.
Remove the saturated charcoal filter by releasing the fixing
hooks
Fit the new filter and fasten it in its correct position.
Put the metal grease filters in their seats.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
Extract the lamp from the Support.
Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
Refit the Support, fixing it in place with the two screws re-
moved as above.