FLOOR PROTECTOR
This heater must have a non-combustible oor protector
(ember protection) installed beneath it if the oor is of
combustible material. If a oor pad is used, it should be UL
listed or equal. The oor pad or non-combustible surface
should be large enough to extend under the stove and
beyond each side as indicated. If there is a horizontal run
of ue pipe, there needs to be oor protection under it that
extends two inches beyond either side of the pipe.
REAR
FRONT
SIDE
SIDE
Front *16” (407 mm)
Sides 8” (204 mm)
Rear 2” (51 mm)
*Canadian Installations require
18” (457 mm)
CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to
combustible materials be strictly adhered to during
installation of the stove.
Do not place any combustible material within 4’ (1.2m)
of the front of the unit.
The clearance between the ue pipe and a wall are valid
only for vertical walls and for vertical ue pipe.
The chimney connector must not pass through an attic
or roof space, closet or similar concealed space, a oor,
or a ceiling.
For Canadian installations, where passage through a
wall, or partition of combustible construction is desired,
the installation must conform to CAN/CSA-B365.
A ue pipe crossing a combustible wall must have a
minimum clearance of 18” (457.2 mm).
To reduce ue clearances from combustible materials,
contact your local safety department.
Floor to ceiling height must be at least 7’ (2.13m).
D
B
A
C
E
F
E
Key in mm
A 17 432
B 21 534
C 20 508
D 29 737
E 14 356
F 22 559
OUTSIDE COMBUSTION AIR
Your wood stove is approved to be installed with an
outside air intake (4FAK) which is necessary for a mobile
home. This type of installation is also required in air tight
houses and houses with negative pressure problems. You
can purchase this option through your heater dealer. Make
sure to specify the part number mentioned in this booklet.
Installation instructions are supplied with the air intake kit.
Outside combustion air may be required if:
1. Your stove does not draw steadily, smoke roll-out
occurs, wood burns poorly, or back-drafts occur
whether or not there is combustion present.
2. Existing fuel-red equipment in the house, such as
replaces or other heating appliances, smell, do
not operate properly, suffer smoke roll-out when
opened, or back-drafts occur whether or not there is
combustion present.
3. Opening a window slightly on a calm (windless) day
alleviates any of the above symptoms.