AIR TUBES
The air tubes assembled in this unit are designed to
provide an accurate mix of secondary air to ensure the
highest eciency. Any damage or deterioration of these
tubes may reduce the eciency of combustion. The air
tubes are held in position by screws or snap pins. Locate
these to either side of the tube and remove it to allow the
tube to be removed and replaced.
BLOWER OPERATION
The variable-speed blower circulates air warmed by the
rebox into the living area to distribute the heat more
evenly. The blower control knob is located on the side of
the blower housing. Turn the knob clockwise to turn the
blower on. The speed is controlled by turning the knob
clockwise for slower speeds and counter-clockwise
for faster speeds. To turn the blower off, turn the speed
control knob fully counter-clockwise. It is recommended
to turn the blower off when the unit is not in operation. The
blower should be removed at the beginning of every “burn
season and air-blown clean, removing any dust or build-up.
CHIMNEY MAINTENANCE
CAUTION:
DO NOT OVERFIRE APPLIANCE. YOU ARE OVERFIRING
IF ANY PART OF THE APPLIANCE GLOWS RED. CLOSE
THE DOOR AND SHUT DAMPER IMMEDIATELY TO
REDUCE THE AIR SUPPLY AND SLOW DOWN THE FIRE.
CAUTION:
SLOW BURNING FIRES FOR EXTENDED USE OR
BURNING GREEN WOOD MAY CAUSE EXCESSIVE
CREOSOTE BUILD-UP. IGNITION OF CREOSOTE
OR OVERFIRING COULD CAUSE A CHIMNEY FIRE.
CHIMNEY FIRES BURN EXTREMELY HOT AND MAY
IGNITE SURROUNDING COMBUSTIBLE MATERIALS.
IN CASE OF A CHIMNEY FIRE, CALL THE FIRE
DEPARTMENT IMMEDIATELY!
CREOSOTE FORMATION AND NEED FOR
REMOVAL
When wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture
to form creosote. The creosote vapors condense in the
relatively cool chimney ue of a slow-burning re. As a
result, creosote residue accumulates on the ue lining.
When ignited this creosote makes an extremely high
temper re. The chimney connector and chimney should
be inspected at least once every two months during the
heating season to determine if a creosote build-up has
occurred. If creosote has accumulated (3 mm or more),
it should be removed to reduce the risk of a chimney
re. We strongly recommend that you install a magnetic
thermometer on your smoke exhaust pipe, approximately
18” above the stove. This thermometer will indicate the
temperature of your gas exhaust fumes within the smoke
exhaust system. The ideal temperature for these gases
is somewhere between 275°F and 500°F. Below these
temperatures, the build-up of creosote is promoted. Above
500°F, heat is wasted since a too large quantity is lost into
the atmosphere.
TO PREVENT CREOSOTE BUILD UP
Always burn dry wood. This allows clean burns and
higher chimney temperatures, therefore less creosote
deposit.
Leave the air control fully open for about 5 min. every
time you reload the stove to bring it back to proper
operating temperatures. The secondary combustion can
only take place if the rebox is hot enough.
Always check for creosote deposit once every two
months and have your chimney cleaned at least once
a year.
If a chimney or creosote re occurs, close all dampers
immediately. Wait for the re to go out and the heater
to cool, then inspect the chimney for damage. If no
damage results, perform a chimney cleaning to ensure
no more creosote deposits is remaining in the chimney.
CAUTION:
A CHIMNEY FIRE MAY CAUSE IGNITION OF WALL
STUDS OR RAFTERS WHICH WERE ASSUMED TO
BE A SAFE DISTANCE AWAY FROM THE CHIMNEY.
IF A CHIMNEY FIRE OCCURS, HAVE YOUR CHIMNEY
INSPECTED BY A QUALIFIED EXPERT BEFORE USING
AGAIN.
NEVER OPERATE THIS PRODUCT WHILE UNATTENDED
OPERATION INSTRUCTIONS
Loading ...
Loading ...
Loading ...