Programmable Thermostat RTH2410
13
1
Damage can occur if the compressor is restarted too soon after
shutdown. This feature forces the compressor to wait 5 minutes before
restarting. During the wait time, the message Cool On or Heat On
flashes on the screen. When the safe wait time has elapsed, the
message stops flashing and the compressor turns on.
2
Adaptive Intelligent Recovery
TM
allows the thermostat to “learn” how
long your furnace or air conditioner takes to reach the set
temperature. Simply program the desired times and desired
temperatures into the schedule. The thermostat will determine when
to activate heating or cooling so that the desired temperature is
attained at the desired time.
v
System Setup (cont’d)
13.
Function
Default
setting
Options
1
Temperature
display format
0
0: Fahrenheit
1: Celsius
2 Time display format 0
0: 12-hour display
1: 24-hour display
3
Heating cycles per
hour
5
2 to 6 cycles per hour
2: 30 min (steam, gravity)
3: 20 min (hot water, 90%+
high-efficiency furnace)
4: 15 min (gas or oil)
5: 12 min (gas or oil)
6: 10 min (electric)
4
Compressor
protection
1
1
0: Off
1: On
5
Adaptive Intelligent
Recovery
2
1
0: Off
1: On
6 System setup 0
0: Conventional system (1H1C)
1: Heat pump system with
auxiliary/backup heat (2H1C)
69-2382ES-01 (RTH2410 5-1-1 QIG) ENG USA.fm Page 13 Monday, October 19, 2009 3:59 PM