Choose the right cable size

fuse, and switch needed is determined by the
maximum current of the unit. The maximum
current is indicated on the nameplate located on
the side panel of the unit. Refer to this nameplate
to choose the right cable, fuse, or switch.
1. Open the front panel of the indoor unit.
2. Using a screwdriver to open the wire box cover
on the right side of the unit. This will reveal
the terminal block.
Terminal block
Wire cover
Screw
Cable clamp
WARNING


LOCATED ON THE BACK OF THE INDOOR UNIT’S
FRONT PANEL.
3. Unscrew the cable clamp below the terminal
block and place it to the side.
4. Facing the back of the unit, remove the plastic
panel on the bottom left-hand side.
5. Feed the signal wire through the slot, from the
back of the unit to the front.
6. Facing the front of the unit, connect the wire
according to the indoor unit’s wiring diagram,

to its corresponding terminal.
CAUTION

dangerous, and can cause the air conditioning unit
to malfunction.
7. After checking to make sure every connection
is secure, use the cable clamp to fasten the
signal cable to the unit. Screw the cable clamp
down tightly.
8. Replace the wire cover on the front of the unit
and the plastic panel on the back.
NOTE ABOUT WIRING


Step 7: Wrap piping and cables
Before passing the piping, drain hose, and the
signal cable through the wall hole, you must bundle
them together to save space, to protect them and
insulate them (Not applicable in North America).
1. Bundle the drain hose, refrigerant pipes, and

Indoor Unit
Space behind unit
Refrigerant piping
Drain hose
Signal wire
Insulation tape

Make sure that the drain hose is at the bottom of
the bundle. Putting the drain hose at the top of the



WIRES
While bundling these items together, do not
intertwine or cross the signal cable with any other
wiring.
2. Use adhesive vinyl tape to attach the drain
hose to the underside of the refrigerant pipes.
3. Use insulation tape to wrap the signal wire,
refrigerant pipes, and drain hose tightly
together. Double-check that all items are
bundled.
Installation