heating of the thermocouple. If it is not, increase the minimum.
Before leaving check all connections for gas leaks with soap and water.
WARNING: Do not use a naked flame for detecting leaks.
Ignite all burners both individually and combined to ensure correct operation of gas valves,
burners and ignition.
Abnormal operation
If the appliance cannot be adjusted to perform correctly, it is an abnormal situation and you
should contact the authorised service provider.
Any of the following are considered to be abnormal operation and may require servicing:
•• Yellow tipping of the burner flame.
•• Sooting up of utensils.
•• Burners not igniting properly.
•• Burners failing to remain alight.
•• Burners being extinguished by oven door.
•• Gas valves which are difficult to turn.
Ventilation of room
The air needed for burning is received from room air and the gases emitted are given directly
in room. For safe operation of your product, good room ventilation is a precondition. If no
window or room to be utilized for room ventilation is available, additional ventilation should be
installed. However, room has a door opening outside, it is no needed to vent holes.
Room size Ventilating opening
Smaller than 5 m³ min. 100 cm²
Between 5 m³ - 10 m³ min. 50 cm²
Bigger than 10 m³ no need
In basement or cellar min. 65 cm²